Siemens 3RV2142-4RA10 65…84 MPCB With Relay Funcation Size S3 3RV

₹18,738.00 ₹22,110.84
In stock
More Information
Product NameSiemens 3RV2142-4RA10 65…84 MPCB With Relay Funcation Size S3 3RV
Weight2.339000
BrandSiemens
Test CertificateNo
COUNTRY OF MANUFACTUREIndia
SizesS3
Model3RV2142-4RA10
HSN Code85362030
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryElectrical, Circuit Breakers & Fuses, MPCB
Product CodeTNB-0712
Freight Extra (Godown Delivery)
In Stock ( 200 Units )

Siemens 3RV2142-4RA10 65…84 MPCB With Relay Funcation Size S3 3RV

 

Description

Circuit Breaker Size S3 For Motor Protection Class 10 With Overload Relay Function A-Release 65...84 A N-Release 1170 A Screw Terminal Increased Switching Capacity 100 kA

 

Product Brand Name  Sirius
Product Designation  Circuit Breaker
Design Of The Product For Motor Protection With Overload Relay Function
Product Type Designation  3RV2

 

General Technical Data
Size Of The Circuit-Breaker S3
Size Of Contactor Can Be Combined Company-Specific  S3
Product Extension Auxiliary Switch  Yes
Power Loss [W] For Rated Value Of The Current
At AC In Hot Operating State  34 W
At AC In Hot Operating State Per Pole 11.3 W
Insulation Voltage With Degree Of Pollution 3 At AC Rated Value  1000 V
Surge Voltage Resistance Rated Value 8 kV
Shock Resistance According To IEC 60068-2-27 25g / 11 ms Sinus
Mechanical Service Life (Operating Cycles)
Of The Main Contacts Typical  25 000
Of Auxiliary Contacts Typical  25 000
Electrical Endurance (Operating Cycles) Typical  25 000
Reference Code According To IEC 81346-2 Q
Substance Prohibitance (Date)  03/01/2017
SVHC Substance Name  Lead - 7439-92-1
Weight 2.339 kg
Ambient Conditions
Installation Altitude At Height Above Sea Level Maximum  2 000 m
Ambient Temperature
During Operation  -20 ... +60 °C
During Storage -50 ... +80 °C
During Transport  -50 ... +80 °C
Relative Humidity During Operation 10 ... 95 %
Environmental Footprint
Global Warming Potential [CO2 Eq] Total  283.24 kg
Global Warming Potential [CO2 Eq] During Manufacturing 18.5 kg
Global Warming Potential [CO2 Eq] During Sales  1.24 kg
Global Warming Potential [CO2 Eq] During Operation  265 kg
Global Warming Potential [CO2 Eq] After End Of Life  -1.5 kg
Siemens Eco Profile (SEP)  Siemens EcoTech
Main Circuit
Number Of Poles For Main Current Circuit  3
Adjustable Current Response Value Current Of The Currentdependent Overload Release 65 ... 84 A
Operating Voltage
Rated Value  20 ... 690 V
At AC-3 Rated Value Maximum  690 V
At AC-3e Rated Value Maximum  690 V
Operating Frequency Rated Value  50 ... 60 Hz
Operational Current Rated Value  84 A
Operational Current
At AC-3 at 400 V Rated Value  84 A
At AC-3e at 400 V Rated Value  84 A
Pperating Power
At AC-3
At 230 V Rated Value 22 kW
At 400 V Rated Value 45 kW
At 500 V Rated Value 55 kW
At 690 V Rated Value 75 kW
At AC-3e
At 230 V Rated Value 22 kW
At 400 V Rated Value 45 kW
At 500 V Rated Value 55 kW
At 690 V Rated Value 75 kW
Operating Frequency
At AC-3 Maximum  15 1/h
At AC-3e Maximum  15 1/h
Protective And Monitoring Functions
Product Function
Ground Fault Detection No
Phase Failure Detection  Yes
Trip Class Class 10
Design Of The Overload Release Thermal
Maximum Short-Circuit Current Breaking Capacity (Icu)
At AC at 240 V Rated Value 100 kA
At AC at 400 V Rated Value 100 kA
At AC at 500 V Rated Value 10 kA
At AC at 690 V Rated Value 6 kA
Operating Short-Circuit Current Breaking Capacity (Ics) At AC
At 240 V Rated Value 100 kA
At 400 V Rated Value 50 kA
At 500 V Rated Value 5 kA
At 690 V Rated Value 3 kA
Response Value Current Of Instantaneous Short-Circuit Trip Unit  1170 A
UL/CSA Ratings
Full-Load Current (FLA) For 3-Phase AC Motor
At 480 V Rated Value 84 A
At 600 V Rated Value 84 A
Yielded Mechanical Performance [Hp]
For Single-Phase AC Motor
At 110/120 V Rated Value  7.5 hp
At 230 V Rated Value  15 hp
For 3-Phase AC Motor
At 200/208 V Rated Value  25 hp
At 220/230 V Rated Value 30 hp
At 460/480 V Rated Value 60 hp
At 575/600 V Rated Value 75 hp
Short-Circuit Protection
Product Function Short Circuit Protection  Yes
Design Of The Short-Circuit Trip  Magnetic
Installation/ Mounting/ Dimensions
Mounting Position  Any
Fastening Method  Screw And Snap-On Mounting Onto 35 mm DIN Rail According to DIN EN 60715
Height 165 mm
Width  90 mm
Depth  176 mm
Required Spacing
With Side-By-Side Mounting At The Side  0 mm
For Grounded Parts At 400 V
Downwards  70 mm
Upwards  70 mm
At The Side  10 mm
For Live Parts At 400 V
Downwards  70 mm
Upwards  70 mm
At The Side 10 mm
For Grounded Parts At 500 V
Downwards  70 mm
Upwards  70 mm
At The Side 10 mm
For Live Parts At 500 V
Downwards  110 mm
Upwards  110 mm
At The Side 10 mm
For Grounded Parts At 690 V
Downwards  150 mm
Upwards  150 mm
Backwards  0 mm
At The Side 30 mm
Forwards  0 mm
For Live Parts At 690 V
Downwards  150 mm
Upwards  150 mm
Backwards  0 mm
At The Side 30 mm
Forwards 0 mm
Connections/ Terminals
Type Of Electrical Connection
For Main Current Circuit  Screw-Type Terminals
For Auxiliary And Control Circuit Screw-Type Terminals
Arrangement Of Electrical Connectors For Main Current Circuit Top And Bottom
Type Of Connectable Conductor Cross-Sections
For Main Contacts
Solid  2x (2.5 ... 16 mm²)
Solid Or Stranded 2x (2,5 ... 50 mm²), 1x (10 ... 70 mm²)
Finely Stranded With Core End Processing 2x (2.5 ... 35 mm²), 1x (2.5 ... 50 mm²)
Finely Stranded Without Core End Processing 2x (10 ... 35 mm²), 1x (10 ... 50 mm²)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
Finely Stranded With Core End Processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
For AWG Cables For Auxiliary Contacts 2x (20 ... 16), 2x (18 ... 14)
Tightening Torque
For Main Contacts For Ring Cable Lug  4.5 ... 6 N·m
Outer Diameter Of The Usable Ring Cable Lug Maximum  19 mm
Tightening Torque
For Main Contacts With Screw-Type Terminals  4.5 ... 6 N·m
For Auxiliary Contacts With Screw-Type Terminals  0.8 ... 1.2 N·m
Design Of The Thread Of The Connection Screw
Of The Auxiliary And Control Contacts  M3
Safety Related Data
Product Function Suitable For Safety Function Yes
Suitability For Use
Safety-Related Switching On  No
Safety-Related Switching OFF  Yes
Service Life Maximum  10 a
Test Wear-Related Service Life Necessary  Yes
Proportion Of Dangerous Failures
With Low Demand Rate According To SN 31920  40 %
With High Demand Rate According To SN 31920  50 %
B10 Value With High Demand Rate According To SN 31920  5 000
Failure Rate [FIT] With Low Demand Rate According To SN 31920 50 FIT
ISO 13849
Device Type According To ISO 13849-1  3
Overdimensioning According To ISO 13849-2 Necessary  Yes
IEC 61508
Safety Device Type According To IEC 61508-2  Type A
T1 Value
For Proof Test Interval Or Service Life According To IEC 61508 10 a
Electrical Safety
Protection Class IP On The Front According To IEC 60529  IP20
Touch Protection On The Front According To IEC 60529  Finger-Safe, For Vertical Contact From The Front
Display
Display Version For Switching Status  Handle

 

Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:Siemens 3RV2142-4RA10 65…84 MPCB With Relay Funcation Size S3 3RV