Description

Circuit Breaker Size S0 For Motor Protection, Class 10 With Overload Relay Function A-Release 27...32 A N-Release 400 A Screw Terminal Standard Switching Capacity

 

Product Brand Name Sirius
Product Designation  Circuit Breaker
Design Of The Product  For Motor Protection With Overload Relay Function
Product Type Designation  3RV2

 

General Technical Data
Size Of The Circuit-Breaker S0
Size Of Contactor Can Be Combined Company-Specific  S00, S0
Product Extension Auxiliary Switch  Yes
Power Loss [W] For Rated Value Of The Current
At AC In Hot Operating State  13.25 W
At AC In Hot Operating State Per Pole  4.4 W
Insulation Voltage With Degree Of Pollution 3 At AC Rated Value  690 V
Surge Voltage Resistance Rated Value  6 kV
Shock Resistance According To IEC 60068-2-27  25g / 11 ms
Mechanical Service Life (Operating Cycles)
Of The Main Contacts Typical  100 000
Of Auxiliary Contacts Typical 100 000
Electrical Endurance (Operating Cycles) Typical  100 000
Reference Code According To IEC 81346-2  Q
Substance Prohibitance (Date)  10/01/2009
Weight  0.436 kg
Ambient Conditions
Installation Altitude At Height Above Sea Level Maximum  2 000 m
Ambient Temperature
During Operation -20 ... +60 °C
During Storage -50 ... +80 °C
During Transport -50 ... +80 °C
Relative Humidity During Operation  10 ... 95 %
Environmental Footprint
Global Warming Potential [CO2 Eq] Total  75.078 kg
Global Warming Potential [CO2 Eq] During Manufacturing  2.68 kg
Global Warming Potential [CO2 Eq] During Sales  0.143 kg
Global Warming Potential [CO2 Eq] During Operation 72.7 kg
Global Warming Potential [CO2 Eq] After End Of Life -0.445 kg
Siemens Eco Profile (SEP) Siemens EcoTech
Main circuit
Number Of Poles For Main Current Circuit  3
Adjustable Current Response Value Current Of The Currentdependent Overload Release 27 ... 32 A
Operating Voltage
Rated Value  20 ... 690 V
At AC-3 Rated Value Maximum  690 V
At AC-3e Rated Value Maximum  690 V
Operating Frequency Rated Value  50 ... 60 Hz
Operational Current Rated Value  32 A
Operational Current
At AC-3 at 400 V Rated Value  32 A
At AC-3e at 400 V Rated Value  32 A
Operating Power
At AC-3
At 230 V Rated Value 7.5 kW
At 400 V Rated Value 15 kW
At 500 V Rated Value 18.5 kW
At 690 V Rated Value 30 kW
At AC-3e
At 230 V Rated Value 7.5 kW
At 400 V Rated Value 15 kW
At 500 V Rated Value 18.5 kW
At 690 V Rated Value 30 kW
Operating Frequency
At AC-3 Maximum  15 1/h
At AC-3e Maximum  15 1/h
Auxiliary Circuit
Design Of The Auxiliary Switch  Laterally
Number Of NC Contacts For Auxiliary Contacts  0
Number Of NO Contacts For Auxiliary Contacts  0
Number Of CO Contacts For Auxiliary Contacts  0
Operational Current Of Auxiliary Contacts At AC-15
At 24 V  1.5 A
At 230 V  1.5 A
Operational Current Of Auxiliary Contacts At DC-13
At 24 V 1 A
Protective And Monitoring Functions
Product Function
Ground Fault Detection No
Phase Failure Detection  Yes
Trip Class Class 10
Design Of The Overload Release  Thermal
Maximum Short-Circuit Current Breaking Capacity (Icu)
At AC at 240 V Rated Value 100 kA
At AC at 400 V Rated Value 55 kA
At AC at 500 V Rated Value 10 kA
At AC at 690 V Rated Value 4 kA
Operating Short-Circuit Current Breaking Capacity (Ics) At AC
At 240 V Rated Value 100 kA
At 400 V Rated Value 25 kA
At 500 V Rated Value 5 kA
At 690 V Rated Value 2 kA
Response Value Current Of Instantaneous Short-Circuit Trip Unit  400 A
UL/CSA Ratings
Full-Load Current (FLA) For 3-Phase AC Motor
At 480 V Rated Value 32 A
At 600 V Rated Value 32 A
Yielded Mechanical Performance [Hp]
For Single-Phase AC Motor
At 110/120 V Rated Value 2 hp
At 230 V Rated Value 5 hp
For 3-Phase AC Motor
At 200/208 V Rated Value 7.5 hp
At 220/230 V Rated Value 10 hp
At 460/480 V Rated Value 20 hp
Contact Rating Of Auxiliary Contacts According To UL  C600 / R300
Short-Circuit Protection
Product Function Short Circuit Protection  Yes
Design Of The Short-Circuit Trip  Magnetic
Design Of The Fuse Link
For Short-Circuit Protection Of The Auxiliary Switch Required Fuse gL/gG: 6 A, Quick: 10 A
Design Of The Fuse Link For IT Network For Short-Circuit Protection Of The Main Circuit
At 400 V  gL/gG 63 A
At 500 V  gL/gG 63 A
At 690 V  gL/gG 63 A
Installation/ Mounting/ Dimensions
Mounting Position  Any
Fastening Method  Screw And Snap-On Mounting Onto 35 mm DIN Rail According To DIN EN 60715
Height  97 mm
Width 65 mm
Depth 97 mm
Required Spacing
With Side-By-Side Mounting At The Side  0 mm
For Grounded Parts At 400 V
Downwards  30 mm
Upwards  30 mm
At The Side  9 mm
For Live Parts At 400 V
Downwards  30 mm
Upwards  30 mm
At The Side 9 mm
For Grounded Parts At 500 V
Downwards  30 mm
Upwards  30 mm
At The Side 9 mm
For Live Parts At 500 V
Downwards  30 mm
Upwards  30 mm
At The Side 9 mm
For Grounded Parts At 690 V
Downwards  50 mm
Upwards  50 mm
Backwards  0 mm
At The Side 30 mm
Forwards  0 mm
For Live Parts At 690 V
Downwards  50 mm
Upwards  50 mm
Backwards  0 mm
At The Side 30 mm
Forwards  0 mm
Connections/ Terminals
For Main Current Circuit  Screw-Type Terminals
For Auxiliary And Control Circuit  Screw-Type Terminals
Arrangement Of Electrical Connectors For Main Current Circuit Top And Bottom
Type Of Connectable Conductor Cross-Sections
For Main Contacts
Solid Or Stranded 2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²)
Finely Stranded With Core End Processing  2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
For AWG Cables For Main Contacts  2x (16 ... 12), 2x (14 ... 8)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
Solid Or Stranded  2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Finely Stranded With Core End Processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
For AWG Cables For Auxiliary Contacts 2x (20 ... 16), 2x (18 ... 14)
Tightening Torque
For Main Contacts With Screw-Type Terminals 2 ... 2.5 N·m
For Auxiliary Contacts With Screw-Type Terminals  0.8 ... 1.2 N·m
Design Of Screwdriver Shaft Diameter 5 to 6 mm
Size Of The Screwdriver Tip  Pozidriv Size 2
Design Of The Thread Of The Connection Screw
For Main Contacts  M4
Of The Auxiliary And Control Contacts M3
Safety Related Data
Product Function Suitable For Safety Function  Yes
Suitability For Use
Safety-Related Switching On  No
Safety-Related Switching OFF  Yes
Service Life Maximum  10 a
Test Wear-Related Service Life Necessary Yes
Proportion Of Dangerous Failures
With Low Demand Rate According To SN 31920  40 %
With High Demand Rate According To SN 31920 50 %
B10 Value With High Demand Rate According To SN 31920  5 000
Failure Rate [FIT] With Low Demand Rate According To SN 31920 50 FIT
ISO 13849
Device Type According To ISO 13849-1  3
Overdimensioning According To ISO 13849-2 Necessary  Yes
IEC 61508
Safety Device Type According To IEC 61508-2  Type A
T1 Value
For Proof Test Interval Or Service Life According To IEC 61508 10 a
Electrical Safety
Protection Class IP On The Front According To IEC 60529  IP20
Touch Protection On The Front According To IEC 60529 Finger-Safe, For Vertical Contact From The Front
Display
Display Version For Switching Status  Handle

 

Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:Siemens 3RV2121-4EA10 27…32 MPCB With Relay Funcation Size S0 3RV
Your Rating
WA button WA button