Product Name | Siemens 3RV2011-1HA10 5.5…8 MPCB With Standard Release Size S00 3RV |
---|---|
Weight | 0.350000 |
Brand | Siemens |
Test Certificate | No |
COUNTRY OF MANUFACTURE | India |
Sizes | S00 |
Model | 3RV2011-1HA10 |
HSN Code | 85362030 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Electrical, Circuit Breakers & Fuses, MPCB |
Product Code | TNB-0644 |
Description
Circuit Breaker Size S00 For Motor Protection, Class 10 A-Release 5.5...8 A N-Release 104 A Screw Terminal Standard Switching Capacity
Product Brand Name | Sirius |
Product Designation | Circuit Breaker |
Design Of The Product | For Motor Protection |
Product Type Designation | 3RV2 |
General Technical Data | |
Size Of The Circuit-Breaker | S00 |
Size Of Contactor Can Be Combined Company-Specific | S00, S0 |
Product Extension Auxiliary Switch | Yes |
Power Loss [W] For Rated Value Of The Current | |
At AC In Hot Operating State | 9.25 W |
At AC In Hot Operating State Per Pole | 3.1 W |
Insulation Voltage With Degree Of Pollution 3 At AC Rated Value | 690 V |
Surge Voltage Resistance Rated Value | 6 kV |
Shock Resistance According To IEC 60068-2-27 | 25g / 11 ms |
Mechanical Service Life (Operating Cycles) | |
Of The Main Contacts Typical | 100 000 |
Of Auxiliary Contacts Typical | 100 000 |
Electrical Endurance (Operating Cycles) Typical | 100 000 |
Reference Code According To IEC 81346-2 | Q |
Substance Prohibitance (Date) | 10/01/2009 |
SVHC Substance Name | Lead - 7439-92-1 |
Weight | 0.35 kg |
Ambient Conditions | |
Installation Altitude At Height Above Sea Level Maximum | 2 000 m |
Ambient Temperature | |
During Operation | -20 ... +60 °C |
During Storage | -50 ... +80 °C |
During Transport | -50 ... +80 °C |
Relative Humidity During Operation | 10 ... 95 % |
Environmental Footprint | |
Global Warming Potential [CO2 Eq] Total | 74.698 kg |
Global Warming Potential [CO2 Eq] During Manufacturing | 1.98 kg |
Global Warming Potential [CO2 Eq] During Sales | 0.134 kg |
Global Warming Potential [CO2 Eq] During Operation | 72.7 kg |
Global Warming Potential [CO2 Eq] After End Of Life | -0.116 kg |
Siemens Eco Profile (SEP) | Siemens EcoTech |
Main Circuit | |
Number Of Poles For Main Current Circuit | 3 |
Adjustable Current Response Value Current Of The Currentdependent Overload Release | 5.5 ... 8 A |
Operating Voltage | |
Rated Value | 20 ... 690 V |
At AC-3 Rated Value Maximum | 690 V |
At AC-3e Rated Value Maximum | 690 V |
Operating Frequency Rated Value | 50 ... 60 Hz |
Operational Current Rated Value | 8 A |
Operational Current | |
At AC-3 at 400 V Rated Value | 8 A |
At AC-3e at 400 V Rated Value | 8 A |
Operating Power | |
at AC-3 | |
At 230 V Rated Value | 1.5 kW |
At 400 V Rated Value | 3 kW |
At 500 V Rated Value | 4 kW |
At 690 V Rated Value | 5.5 kW |
at AC-3e | |
At 230 V Rated Value | 1.5 kW |
At 400 V Rated Value | 3 kW |
At 500 V Rated Value | 4 kW |
At 690 V Rated Value | 5.5 kW |
Operating Frequency | |
At AC-3 Maximum | 15 1/h |
At AC-3e Maximum | 15 1/h |
Auxiliary Circuit | |
Number Of NC Contacts For Auxiliary Contacts | 0 |
Number Of NO Contacts For Auxiliary Contacts | 0 |
Number Of CO Contacts For Auxiliary Contacts | 0 |
Protective And Monitoring Functions | |
Product Function | |
Ground Fault Detection | No |
Phase Failure Detection | Yes |
Trip Class | Class 10 |
Design Of The Overload Release | Thermal |
Maximum Short-Circuit Current Breaking Capacity (Icu) | |
At AC at 240 V Rated Value | 100 kA |
At AC at 400 V Rated Value | 100 kA |
At AC at 500 V Rated Value | 42 kA |
At AC at 690 V Rated Value | 6 kA |
Operating Short-Circuit Current Breaking Capacity (Ics) At AC | |
At 240 V Rated Value | 100 kA |
At 400 V Rated Value | 100 kA |
At 500 V Rated Value | 42 kA |
At 690 V Rated Value | 4 kA |
Response Value Current Of Instantaneous Short-Circuit Trip Unit | 104 A |
UL/CSA Ratings | |
Full-Load Current (FLA) For 3-Phase AC Motor | |
At 480 V Rated Value | 8 A |
At 600 V Rated Value | 8 A |
Yielded Mechanical Performance [Hp] | |
For Single-Phase AC Motor | |
At 110/120 V Rated Value | 0.33 Hp |
At 230 V Rated Value | 1 hp |
For 3-Phase AC Motor | |
At 200/208 V Rated Value | 2 Hp |
At 220/230 V Rated Value | 2 Hp |
At 460/480 V Rated Value | 5 Hp |
At 575/600 V Rated Value | 5 Hp |
Short-Circuit Protection | |
Product Function Short Circuit Protection | Yes |
Design Of The Short-Circuit Trip | Magnetic |
Design Of The Fuse Link For IT Network For Short-Circuit | |
Protection Of The Main Circuit | |
At 400 V | gL/gG 50 A |
At 500 V | gL/gG 40 A |
At 690 V | gL/gG 35 A |
Installation/ Mounting/ Dimensions | |
Mounting Position | Any |
Fastening Method | Screw And Snap-On Mounting Onto 35 mm DIN Rail According To DIN EN 60715 |
Height | 97 mm |
Width | 45 mm |
Depth | 97 mm |
Required Spacing | |
With Side-By-Side Mounting At The Side | 0 mm |
For Grounded Parts At 400 V | |
Downwards | 30 mm |
Upwards | 30 mm |
At The Side | 9 mm |
For Live Parts At 400 V | |
Downwards | 30 mm |
Upwards | 30 mm |
At The Side | 9 mm |
For Grounded Parts At 500 V | |
Downwards | 30 mm |
Upwards | 30 mm |
At The Side | 9 mm |
For Live Parts At 500 V | |
Downwards | 30 mm |
Upwards | 30 mm |
At The Side | 9 mm |
For Grounded Parts At 690 V | |
Downwards | 50 mm |
Upwards | 50 mm |
Backwards | 0 mm |
At The Side | 30 mm |
Forwards | 0 mm |
For Live Parts At 690 V | |
Downwards | 50 mm |
Upwards | 50 mm |
Backwards | 0 mm |
At The Side | 30 mm |
Forwards | 0 mm |
Connections/ Terminals | |
Type Of Electrical Connection | |
For Main Current Circuit | Screw-Type Terminals |
Arrangement Of Electrical Connectors For Main Current Circuit | Top And Bottom |
Type Of Connectable Conductor Cross-Sections | |
For Main Contacts | |
Solid Or Stranded | 2x (0,75 ... 2,5 mm²), 2x 4 mm² |
Finely Stranded With Core End Processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
For AWG Cables For Main Contacts | 2x (18 ... 14), 2x 12 |
Tightening Torque | |
For Main Contacts With Screw-Type Terminals | 0.8 ... 1.2 N·m |
Design Of Screwdriver Shaft | Diameter 5 to 6 mm |
Size Of The Screwdriver Tip | Pozidriv Size 2 |
Design Of The Thread Of The Connection Screw | |
For Main Contacts | M3 |
Safety Related Data | |
Product Function Suitable For Safety Function | Yes |
Suitability For Use | |
Safety-Related Switching On | No |
Safety-Related Switching OFF | Yes |
Service Life Maximum | 10 a |
Test Wear-Related Service Life Necessary | Yes |
Proportion Of Dangerous Failures | |
With Low Demand Rate According To SN 31920 | 40 % |
With High Demand Rate According To SN 31920 | 50 % |
B10 Value With High Demand Rate According To SN 31920 | 5 000 |
Failure Rate [FIT] With Low Demand Rate According To SN 31920 | 50 FIT |
ISO 13849 | |
Device Type According To ISO 13849-1 | 3 |
Overdimensioning According To ISO 13849-2 Necessary | Yes |
IEC 61508 | |
Safety Device Type According To IEC 61508-2 | Type A |
T1 Value | |
For Proof Test Interval Or Service Life According To IEC 61508 | 10 a |
Electrical Safety | |
Protection Class IP On The Front According To IEC 60529 | IP20 |
Touch Protection On The Front According To IEC 60529 | Finger-Safe, For Vertical Contact From The Front |
Display | |
Display Version For Switching Status | Handle |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping & Delivery Policy: |
1. | 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
4. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |