Siemens 3RH1921-1CA10 Auxiliary Contact Block 1P 1NO Size : S6 - S12
₹130.50 ₹153.99
In stock
Product Name | Siemens 3RH1921-1CA10 Auxiliary Contact Block 1P 1NO Size : S6 - S12 |
---|---|
Weight | 0.020000 |
COUNTRY OF MANUFACTURE | India |
Brand | Siemens |
Model | 3RH1921-1CA10 |
Sizes | S6 - S12 |
HSN Code | 85389000 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Electrical, Relays & Contactor, Accessories, Contact Block |
Product Code | TNB-0563 |
In Stock ( 200 Units )
Siemens 3RH1921-1CA10 Auxiliary Contact Block 1P 1NO Size : S6 - S12
Description
Front-Side Auxiliary Switch, 1 No Contact, Screw Terminal, For Contactors 3Rt1
Product Brand Name | Sirius |
Product Category | Auxiliary Switch |
Product Designation | Auxiliary Switch |
Design Of The Product | For Snapping Onto The Front |
Product Type Designation | 3Rh19 |
Suitability For Use | For 3Rt10, 3Rt12, 3Rt145, 3Rt146, 3Rt147 |
General Technical Data |
Insulation Voltage With Degree Of Pollution 3 At Ac Rated Value | 690 V |
Surge Voltage Resistance Rated Value | 6 Kv |
Protection Class IP On The Front | Ip20 |
Mechanical Service Life (Operating Cycles) Typical | 10 000 000 |
Electrical Endurance (Operating Cycles) At AC-15 At 230 V Typical | 200 000 |
Substance Prohibitance (Date) | 07/01/2006 |
Weight | 0.02 kg |
Number Of NC Contacts For Auxiliary Contacts | |
Instantaneous Contact | 0 |
Number Of NO Contacts For Auxiliary Contacts | |
Instantaneous Contact | 1 |
Number Of CO Contacts Of Auxiliary Contacts Instantaneous Contact | 0 |
Operational Current At AC-15 At 690 V Rated Value | 1 A |
Operational Current Of Auxiliary Contacts At AC-12 | |
at 24 V | 10 A |
at 230 V | 10 A |
operational current of auxiliary contacts at AC-14 | |
at 125 V | 6 A |
at 250 V | 6 A |
Operational Current Of Auxiliary Contacts At AC-12 Maximum | 10 A |
Operational Current Of Auxiliary Contacts At AC-15 | |
at 24 V | 6 A |
at 230 V | 6 A |
at 400 V | 3 A |
Operational Current Of Auxiliary Contacts At DC-12 | |
at 24 V | 10 A |
at 110 V | 3 A |
at 220 V | 1 A |
Operational Current With 2 Current Paths In Series At DC-12 | |
at 24 V rated value | 10 A |
at 60 V rated value | 10 A |
at 110 V rated value | 4 A |
at 220 V rated value | 2 A |
at 440 V rated value | 1.3 A |
at 600 V rated value | 0.65 A |
Operational Current With 3 Current Paths In Series At DC-12 | |
at 24 V rated value | 10 A |
at 60 V rated value | 10 A |
at 110 V rated value | 10 A |
at 220 V rated value | 3.6 A |
at 440 V rated value | 2.5 A |
at 600 V rated value | 1.8 A |
Operational Current With 2 Current Paths In Series At DC-13 | |
at 24 V rated value | 10 A |
at 60 V rated value | 3.5 A |
at 110 V rated value | 1.3 A |
at 220 V rated value | 0.9 A |
at 440 V rated value | 0.2 A |
at 600 V rated value | 0.1 A |
Operational Current With 3 Current Paths In Series At DC-13 | |
at 24 V rated value | 10 A |
at 60 V rated value | 4.7 A |
at 110 V rated value | 3 A |
at 220 V rated value | 1.2 A |
at 440 V rated value | 0.5 A |
at 600 V rated value | 0.26 A |
Operational Current Of Auxiliary Contacts At DC-13 | |
at 24 V | 6 A |
at 48 V | 2 A |
at 60 V | 2 A |
at 110 V | 1 A |
at 125 V | 0.9 A |
at 220 V | 0.3 A |
at 250 V | 0.3 A |
Contact Reliability Of Auxiliary Contacts | 1 Faulty Switching Per 100 Million (17 V, 1 mA) |
Ambient Conditions | |
Ambient Temperature | |
During Operation | -25 ... +60 °C |
During Storage | -55 ... +80 °C |
Safety Related Data | |
Product Function | |
Mirror Contact According To IEC 60947-4-1 | Yes; With 3RT1 |
Positively Driven Operation According To IEC 60947-5-1 | No |
Installation/ Mounting/ Dimensions | |
Fastening Method | Snap-On Mounting |
Height | 38 mm |
Width | 10 mm |
Depth | 51 mm |
Connections/ Terminals | |
Type Of Electrical Connection For Auxiliary And Control Circuit | Screw-Type Terminals |
Connectable Conductor Cross-Section For Auxiliary Contacts | |
Solid Or Stranded | 0.5 ... 2.5 mm² |
Finely Stranded With Core End Processing | 0.5 ... 2.5 mm² |
Type Of Connectable Conductor Cross-Sections | |
For Auxiliary Contacts | |
Solid Or Stranded | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
Finely Stranded With Core End Processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
For AWG Cables For Auxiliary Contacts | 2x (20 ... 16), 2x (18 ... 14) |
AWG Number As Coded Connectable Conductor Cross Section For Auxiliary Contacts | 20 ... 14 |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping & Delivery Policy: |
1. | 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
4. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |