Schneider LC1D50 / 220/415VAC coil Power Contactors 3 Pole "D" Series
₹5,457.90 ₹6,440.32
In stock
STOCK : In stock (%1 Units)
Product Name | Schneider LC1D50 / 220/415VAC coil Power Contactors 3 Pole "D" Series |
---|---|
Weight | 1.000000 |
Brand | Schneider Electric |
Test Certificate | No |
COUNTRY OF MANUFACTURE | India |
HSN Code | 85369090 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Electrical, Relays & Contactor, Power Contactor |
Product Code | TNB-0333 |
Schneider LC1D50 / 220/415VAC coil Power Contactors 3 Pole "D" Series
LC1D50D7
contactor TeSys Deca - 3 poles - AC-3 440V
50 A - coil 42 V AC
Main | |
Range | TeSys |
Range of product | TeSys Deca |
Product or component type | Contactor |
Device short name | LC1D |
Contactor application | Resistive load Motor control |
Utilisation category | AC-1 AC-3 AC-4 AC-3 |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz |
[Ie] rated operational current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 50 A (at <60 °C) DC AC-3 for power circuit 80 A (at <60 °C) DC AC-1 for power circuit |
[Uc] control circuit voltage | 42 V DC |
Complementary | |
Motor power kW | 25 KW at 415 V AC 50 Hz (AC-3) 30 KW at 440 V AC 50 Hz (AC-3) 30 KW at 500 V AC 50 Hz (AC-3) 33 KW at 660...690 V AC 50 Hz (AC-3) 15 KW at 220...230 V AC 50 Hz (AC-3) 11 KW at 400 V AC 50 Hz (AC-4) 30 KW at 1000 V AC 50 Hz (AC-3) 25 KW at 415 V AC 50 Hz 22 KW at 380...400 V AC 50 Hz |
Motor power hp | 7.5 Hp at 230/240 V AC 60 Hz for 1 phase motors 15 Hp at 200/208 V AC 60 Hz for 3 phases motors 15 Hp at 230/240 V AC 60 Hz for 3 phases motors 40 Hp at 460/480 V AC 60 Hz for 3 phases motors 40 Hp at 575/600 V AC 60 Hz for 3 phases motors 3 Hp at 115 V AC 60 Hz for 1 phase motors |
Compatibility code | LC1D |
Pole contact composition | 3 NO |
Protective cover | With |
[Ith] conventional free air thermal current | 80 A (at 60 °C) for power circuit 10 A (at 60 °C) for control circuit |
Irms rated making capacity | 140 A AC for control circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 250 A DC for control circuit conforming to IEC 60947-5-1 |
Rated breaking capacity | 900 KA at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 810 A 40 °C - 1 s for power circuit 400 A 40 °C - 10 s for power circuit |
Associated fuse rating | 100 A gG at <= 690 V coordination type 1 for power circuit 100 A gG at <= 690 V coordination type 2 for power circuit conforming- to IEC 60947-5-1 10 A gG for control circuit conforming to IEC 60947-5-1 |
Average impedance | 1.5 Ohm - Ith 80 A 50 Hz for power circuit |
Power dissipation per pole | 9.6 W AC-1 3.7 W AC-3 |
[Ui] rated insulation voltage | Control circuit: 600 V UL certified Power circuit: 600 V CSA certified Power circuit: 600 V UL certified conforming to IEC 60947-1 Control circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V CSA certified conforming to IEC 60947-1 Control circuit: 600 V CSA certified |
Overvoltage category | III |
[Uimp] rated impulse withstand voltage | 6 KV conforming to IEC 60947 |
Safety reliability level | B10d = 20000000 cycles contactor with mechanical load conforming- to EN/ISO 13849-1 |
Mechanical durability | 10000000 Cycles |
Control circuit type | DC standard |
Coil technology | Built-in bidirectional peak limiting diode suppressor |
Control circuit voltage limits | 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz 0.75...1.25 Uc (-40…60 °C):operational DC 0.1...0.3 Uc (-40…70 °C):drop-out DC |
Inrush power in VA | 160 VA cos phi 0.75 (at 20 °C) |
Inrush power in W | 19 W (at 20 °C) |
Hold-in power consumption in VA | 15 VA 50 Hz cos phi 0.3 (at 20 °C) |
Hold-in power consumption in W | 7.4 W at 20 °C |
Heat dissipation | 4…5 W at 50/60 Hz for control circuit |
Operating time | 12...26 ms closing 4...19 ms opening |
Maximum operating rate | 3600 Cyc/Mn 60 °C |
Connections - terminals | Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: rigid without- cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible- with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible- with cable end Power circuit: screw terminals 1 2.5…25 mm² - cable stiffness: rigid Power circuit: screw terminals 2 2.5…16 mm² - cable stiffness: rigid without cable end Power circuit: screw terminals 1 2.5…25 mm² - cable stiffness: flexible without- cable end Power circuit: screw terminals 2 2.5…16 mm² - cable stiffness: flexible without- cable end Power circuit: screw terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end Power circuit: screw terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: rigid Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: rigid |
Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2 Power circuit: 5 N.m - on screw terminal - with screwdriver flat Ø 6 to Ø 8 mm Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver pozidriv No 2 Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm |
Auxiliary contact composition | 1 NO + 1 NC |
Auxiliary contacts type | Type mirror contact 1 NC conforming to IEC 60947-4-1 type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 MA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 Ms on energisation between NC and NO contacts 1.5 Ms on de-energisation between NC and NO contacts |
Mounting support | Plate Plate |
Environment | |
Standards | EN 60947-4-1 IEC 60947-4-1 CSA C22.2 No 14 EN 60947-5-1 UL 508 |
IP degree of protection | IP2X conforming to VDE 0106 IP2X conforming to IEC 60529 |
Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 |
Climatic withstand | Conforming to IACS E10 exposure to damp heat |
Operating altitude | 0...3000 m |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Flame retardance | V1 conforming to UL 94 |
Mechanical robustness | Shocks contactor closed (15 Gn for 11 ms) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor opened (10 Gn for 11 m) |
Height | 122 Mm |
Width | 70 Mm |
Depth | 118 Mm |
Net weight | 2.185 Kg |
Quantity per set | Set of 1 |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 9.5 Cm |
Package 1 Width | 13.5 Cm |
Package 1 Length | 14 Cm |
Package 1 Weight | 1.454 Kg |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping & Delivery Policy: |
1. | 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
4. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |
Write Your Own Review