Schneider LC1D150 / 220/415VAC coil Power Contactors 3 Pole "D" Series

₹18,749.60 ₹22,124.53
In stock
STOCK : In stock (%1 Units)
More Information
Product NameSchneider LC1D150 / 220/415VAC coil Power Contactors 3 Pole "D" Series
Weight1.000000
BrandSchneider Electric
Test CertificateNo
COUNTRY OF MANUFACTUREIndia
HSN Code85369090
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryElectrical, Relays & Contactor, Power Contactor
Product CodeTNB-0357
Freight Extra (Godown Delivery)

Schneider LC1D150 / 220/415VAC coil Power Contactors 3 Pole "D" Series

LC1D150D7
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440
V 150 A - 42 V AC 50/60 Hz coil

Main  
Range TeSys
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-1
AC-4
AC-3
AC-3e
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage 42 V AC 50/60 Hz
   
Complementary  
Motor power kW 40 KW at 220...230 V AC 50/60 Hz (AC-3)
75 KW at 380...400 V AC 50/60 Hz (AC-3)
80 KW at 415...440 V AC 50/60 Hz (AC-3)
90 KW at 500 V AC 50/60 Hz (AC-3)
100 KW at 660...690 V AC 50/60 Hz (AC-3)
75 KW at 1000 V AC 50/60 Hz (AC-3)
22 KW at 400 V AC 50/60 Hz (AC-4)
40 KW at 220...230 V AC 50/60 Hz (AC-3e)
75 KW at 380...400 V AC 50/60 Hz (AC-3e)
80 KW at 415...440 V AC 50/60 Hz (AC-3e)
90 KW at 500 V AC 50/60 Hz (AC-3e)
100 KW at 660...690 V AC 50/60 Hz (AC-3e)
75 KW at 1000 V AC 50/60 Hz (AC-3e)
Motor power hp 40 Hp at 200/208 V AC 50/60 Hz for 3 phases motors
50 Hp at 230/240 V AC 50/60 Hz for 3 phases motors
100 Hp at 460/480 V AC 50/60 Hz for 3 phases motors
125 Hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1660 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1400 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 250 A 40 °C - 10 min for power circuit
580 A 40 °C - 1 min for power circuit
1200 A 40 °C - 10 s for power circuit
1400 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circui
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
315 A gG at <= 690 V coordination type 1 for power circuit
250 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.6 MOhm - Ith 200 A 50 Hz for power circuit
Power dissipation per pole 24 W AC-1
13.5 W AC-3
13.5 W AC-3e
[Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 KV conforming to IEC 60947
Safety reliability level B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 10000000 cycles contactor with mechanical load conforming-
to EN/ISO 13849-1
Mechanical durability 8 Mcycles
Electrical durability 0.85 Mcycles 150 A AC-3 at Ue <= 440 V
1 Mcycles 200 A AC-1 at Ue <= 440 V
0.85 Mcycles 150 A AC-3e at Ue <= 440 V
Control circuit type AC at 50/60 Hz
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3...0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.15 Uc (-40…55 °C):operational AC 50/60 Hz
1...1.15 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA 280…350 VA 60 Hz cos phi 0.9 (at 20 °C)
280…350 VA 50 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA 2…18 VA 60 Hz cos phi 0.9 (at 20 °C)
2…18 VA 50 Hz cos phi 0.9 (at 20 °C)
Heat dissipation 3…4.5 W at 50/60 Hz
Operating time 20...35 ms closing
40...75 ms opening
Maximum operating rate 1200 Cyc/H 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with-
cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible-
with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible-
without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible-
without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end
Power circuit: connector 1 10…120 mm² - cable stiffness: flexible without cable end
Power circuit: connector 2 10…50 mm² - cable stiffness: flexible without cable end
Power circuit: connector 1 10…120 mm² - cable stiffness: flexible with cable end
Power circuit: connector 2 10…50 mm² - cable stiffness: flexible with cable end
Power circuit: connector 1 10…120 mm² - cable stiffness: solid without cable end
Power circuit: connector 2 10…50 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 12 N.m - on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver-
pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 MA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 Ms on de-energisation between NC and NO contact
1.5 Ms on energisation between NC and NO contact
Mounting support Plate
Rail
   
Environment  
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand Conforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C
60…70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height 158 Mm
Width 120 Mm
Depth 136 Mm
Net weight 2.5 Kg
   
Packing Units  
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 16.8 Cm
Package 1 Width 20.8 Cm
Package 1 Length 18.5 Cm
Package 1 Weight 2.44 Kg
Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:Schneider LC1D150 / 220/415VAC coil Power Contactors 3 Pole "D" Series
Your Rating
WA button WA button