Remote Command Center | RCMD LCD annunciator | BOSCH

₹27,500.00 ₹32,450.00
Out of stock
More Information
Product NameRemote Command Center | RCMD LCD annunciator | BOSCH
Weight1.000000
COUNTRY OF MANUFACTUREIndia
BrandBosch
HSN Code85319000
System TypeCONVENTIONAL
materialPlastic (ABS)
Weight_g430 g
ModelFMR-1000-RCMD
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryAlarm System, Addressable System, Fire Safety
Product CodeCPK-0017
Freight Extra (Godown Delivery)
Out Of Stock

LED status indicators
80‑character LCD display
Piezo sounder
Navigation buttons
Operations keys for drill, reset, silence, and acknowledge

The FMR‑1000‑RCMD is a four-conductor LCD annunciator with system control capability for
FCP‑1000 fire panels. The annunciator shows the equivalent LEDs and LCD display. The annunciator
includes a piezo sounder, navigation buttons, and operation keys for drill, reset, silence, and
acknowledge. The navigation functions and the acknowledge key are accessible without restriction—
even when wearing fireman gloves. The keys for reset, silence or drill can be enabled and disabled by the device key lock. The key lock can be disabled to provide full access to the controls.

Functions

Display

The Remote Command Center uses an 80‑character (4 lines x 20 characters) wide viewing-angle LCD
display. The display includes a long‑life LED backlight. The backlight is controlled by the panel, or locally
turned on upon any key press and turned off after a 30 s timeout without key press. Even when AC power is lost, the LED backlight is still turned on if a user is operating the keypad.

System Normal

When no alarms or troubles exist in the system, the Power LED lights steadily, and no other LEDs are lit. The LCD display shows two banner lines, the system status line, and the date and time.

System Off‑normal

If any off‑normal condition exists, the panel displays the number of off‑normal conditions classified in
groups. Groups include fire alarm, gas alarm, supervisory, and trouble. The panel holds up to 255
events for each group at a time. Any restored event is deleted from the list.

Piezo Sounder

The Remote Command Center has a piezo sounder that provides audible indication of the system status. In case of multiple activation, the system status with highest priority is indicated.

Operation Keys

The Remote Command Center has four operation keys:

Acknowledge:

The acknowledge key is accessible without restriction. During an alarm, pressing the key turns off the piezo sounder that is sounding on an annunciator.

Drill:

The Drill key can be enabled and disabled by the device key lock. Drill operation is not available if any fire alarm or supervisory conditions exist. Upon drill operation, a Drill Start Report is logged into the history and, if so programmed, the report is transmitted to the central station. All unbypassed NACs turn on and play the patterns programmed for them. When the drill operation stops, all activated NACs turn off and a Drill Stop Report is logged into the history and, if so programmed, the report is transmitted to the central station. A system reset is automatically performed by stopping the drill so that the panel and all field devices restore to their normal operation.
Reset: The Reset key can be enabled and disabled by the device key lock. When reset operation is initiated, the piezo sounders and activated or silenced outputs turn off. All alarm, supervisory, and troubles caused by activation of SLC points are cleared. Then the control panel tries to reset all points that are in off‑normal status. Not all system trouble conditions are affected by reset operation. Any input points remaining offnormal are re-indicated after reset. Reset operations are logged into the history and, if so programmed, the control panel transmits a reset report to the central
station.
Silence: The silence key can be enabled and disabled by the device key lock. When the silence operation is initiated, the “Silenced" LED turns on, the panel goes into a “Silenced” status, and the piezo sounders on all keypads and annunciators turn off.

Certifications and approvals

Region Regulatory compliance/quality marks
USA UL FSYE: Emergency Alarm System Accessories (ANSI/UL 2017), UOXX: Control
Unit Accessories, System (ANSI/UL 864,
9th edition) FSYE, UOXX
  CSFM see www.boschsecurity.com (the Bosch
website)
  FDNYCoA 6101

Parts included

Quantity Component
1 Remote Command Center in back box with cover frame Enclosure lock and two keys1(replacement key: D102) Tabs with different language versions for LED and key text
1 Hardware pack
1 Literature - Installation and Operation Guide

1
Key code stamped on both lock and key

Technical specifications

Electrical

Voltage (operating) 12 VDC or 24 VDC nominal
Current at 12 VDC
Alarm
Stand-by
150 mA maximum (with annunciator lit and
piezo sounder on)
25 mA maximum (only Power LED on)
Current at 24 VDC
Alarm
Stand-by
120 mA maximum (with annunciator lit and
piezo sounder on)
30 mA maximum (only Power LED on)

Environmental

Environment Indoor, dry
Environment Friendly RoHS compliant
Protection Class IP 30 per IEC 605029
Relative Humidity Up to 95%, non-condensing
Temperature (operating) +32°F to +120°F (0°C to +49°C)
Temperature (storage) -4°F to +140°F (-20°C to +60°C)

Mechanical

Operating and Display Elements

LCD 4‑line x 20‑character display, backlit
LEDs Six [Fire Alarm (red), Gas Alarm (blue),
Power (green), Supervisory (yellow),
Silenced (yellow), and Trouble (yellow)
Keys Acknowledge key, 4 navigation keys
Sounder Built-in piezo sounder

Housing

Material ABS-FR
Color Red

3 | FMR-1000-RCMD LCD annunciator FPA-1000 with control

Dimensions (W x H x D)
Back box
Cover frame
7.40 in x 4.41 in x 1.89 in. (188 mm x
112 mm x 48 mm)
7.40 in x 4.41 in x 2.40 in. (188 mm x
112 mm x 61 mm)
Weight 15.2 oz. (430 g)

Wiring

Cable Entries 3 knockouts for ½ in. diameter conduit connectors on back, bottom and top side
Connections 4 terminals
Wre Gauge 12 AWG to 18 AWG (ISO 0.75 mm2 to 4 mm2)
Wire Type Non-shielded, four conductor wire

All hardware/software product names used in this document are likely to be registered trademarks and must be treated accordingly.

Ordering information

FMR-1000-RCMD LCD annunciator FPA-1000 with control
LCD annunciator with system control capability for use with FPA‑1000 Analog Addressable fire Panels
Order number FMR-1000-RCMD

Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:Remote Command Center | RCMD LCD annunciator | BOSCH
Your Rating
WA button WA button