Output / Input Interface Module | FLM‑420‑O1I1-E | BOSCH

₹2,954.00 ₹3,485.72
In stock
More Information
Product NameOutput / Input Interface Module | FLM‑420‑O1I1-E | BOSCH
Weight1.000000
COUNTRY OF MANUFACTUREIndia
BrandBosch
HSN Code85371000
System TypeCONVENTIONAL
ModelBOSCH-FAS-FLM-420-O1I1-E
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryAlarm System, Fire Safety, Control Module
Product CodeCPK-0105
Freight Extra (Godown Delivery)
In Stock ( 100 Units )

• Semi-conductor output electrically isolated from LSN loop and short-circuit proof
• Max. switchable current per output 700 mA
• Individually selectable input monitoring functions (EOL or contact)
• Maintains LSN loop functions in the event of wire interruption or short-circuit   thanks to two integrated isolators 

The FLM‐420‐O1I1 Output-input Interface Modules are fitted with one output to control external devices and with one monitored input.They are 2‐wire LSN elements for connection to the fire panels FPA‐5000 and FPA‐1200 and offer the enhanced functionality of LSN improved technology.

Functions

The semi-conductor output is electrically isolated from the LSN loop and protected against short circuits.

Functionality of the semi-conductor output

Output power supply

The power supply for loads connected to the output can be selected as:
• Auxiliary power supply from the fire panel
• Or, for FLM‐420‐O1I1-D only: External power supply units

Input monitoring functions

The FLM‐420‐O1I1 Output-input-Interface Module provides two monitoring functions:

1. Monitoring of a line by an EOL resistor
2. Monitoring of a potential‐free contact The input monitoring functions can be selected by setting the corresponding addresses.

Line monitoring with EOL resistor

The EOL resistor has a standard resistance of 3.9 kΩ.
The interface module detects
• Standby
• Triggering in the event of a short circuit
• Triggering in the event of line interruption

The EOL resistor has a standard resistance of 3.9 kΩ.
The interface module detects
• Standby
• Triggering in the event of a short circuit
• Triggering in the event of line interruption

Position            Description

RΣ                    Overall line resistance with RΣ = RL/2 + RL/2 + REOL

RL/2                Line resistance

The following line conditions will be reliably detected if the overall line resistance is within the specified range:

Line condition      Overall line resistance R Σ

Standby                1500 Ω to 5500 Ω

Short circuit          < 800 Ω

Interruption          > 85000 Ω

Contact monitoring

The interface module evaluates the operating conditions "open" or "closed". The normal operating condition can be programmed for each input. Contact
monitoring has a pulse intensity of 8 mA.

Adress switches

The address of the interface module is set using:
• DIP switches in case of the FLM‐420‐O1I1‐E
• Rotary switches in case of the FLM‐420‐O1I1‐D
In improved version LSN mode, the operator can select automatic or manual addressing with or without auto-detection.

Address
rotary
switches
Address
DIP
switches
Mode
0 0 0 0

Loop/stub in improved version LSN mode

with automatic addressing (T-taps not pos-
sible)

0 0 1
-
2 5 4
1 - 254 Loop/stub/T-taps in improved version LSN
mode with manual addressing
CL 0 0 255 Loop/stub in LSN mode classic

LSN features

Integrated isolators ensure that function is maintained in the event of a short circuit or line interruption in the LSN loop. A fault indication is sent to the fire
panel.

Features of LSN improved version

The interface modules in the 420 series offer all the features of improved LSN technology:
• Flexible network structures including T‐tapping without additional elements
• Up to 254 LSN improved elements per loop or stub line
• Unshielded cable can be used

Interface variants

The Output-input Interface Modules are available in various designs:
• FLM‐420‐O1I1‐E in-built version:
– Suitable for standard device boxes according to EN 60670 and
– For a space-saving installation in all devices
• FLM‐420‐O1I1‐D DIN-rail version:
– Suitable for installation on a DIN-rail according to EN 60715 with included       adapter and
– For the FLM‐IFB126‐S surface-mounted housing

Regulatory information

Complies with
• EN 54-17: 2005
• EN 54-18: 2005 + AC:2007

Region   Regulatory compliance/quality marks
Germany VdS G 209070 FLM-420-O1I1-E
  VdS G 209069 FLM-420-O1I1-D
Europe CE FLM-420-O1I1-E
  CE FLM-420-O1I1-D
  CPD 0786-CPD-20714 FLM-420-O1I1-E
  CPD 0786-CPD-20715 FLM-420-O1I1-D
Hungary TMT TMT-36/2010 szamu FLM-420-O8I2-S,
FLM-420-O1I1-E, FLM-420-O1I1-D,
FLM-420-RLE-S
Ukraine MOE UA1.016.0070232-11 FLM-420-O1I1-E
  MOE UA1.016.0070263-11 FLM-420-O1I1-D

Installation/configuration notes

FLM‐420‐O1I1‐D

Description   Connection
IN IN- | IN+ Input 1
OUT POW+ Reference potential (+)
  OUT- Output (switched negative potential)
POWER IN POW+ | 0V Power supply output
LSN b1+ | a- | b2+ LSN (incoming / outgoing)

FLM‐420‐O1I1‐E

Description   Connection
POWER IN POW+ | 0V-

Power supply (interface module and

output)

OUT POW+ Reference potential (+)
  OUT- Output (switched negative potential)
IN - | + Input
LSN SHIELD Cable shielding (if available)
  0V | +U | +U Auxiliary power supply (support
points to loop through)
LSN b2+ | a2- | b1+ | a1- LSN (incoming / outgoing)

• Can be connected to fire panels of LSN improved bus technology.
• Programming is done with the programming software of the fire        panel.
• The LSN connection is established by the two wires of the LSN line.
• The power supply for the output is either fed by the auxiliary power supply from the fire panel or by an external power supply unit. External power
supplies, for FLM‐420‐O1I1-D only, must be free-of-ground.

• The outputs OUT/OUT- are switched against the negative potential of the interface module (POWER IN/0V). The positive potential (OUT/POW+) is either supplied by the auxiliary power (AUX) from the fire panel or by an external power supply unit.
• The maximum switchable voltage of the semi-conductor output is 30 V DC. The maximum switchable current is 700 mA (depending on the external power supply).
• The activation of the input IN has to be carried out electrically isolated from LSN (e.g. with relay contacts, pushbutton, etc.).
• The input must have a minimum activation time of 3.2 s.
• For FLM‐420‐O1I1-D applies: A maximum cable length of 3 m is permitted per input and output.FLM‐420‐O1I1-E must be mounted flush with the connected device.
• The maximum cable length of all inputs connected to the loop or stub is 500 m in total. Additionally, all outputs which are not electrically isolated from LSN must be included in the total line length calculation (e.g. peripherals connected via C points). With UEZ 2000 LSN and UGM 2020, the limitation to 500 m applies to each Network Processing Converter (NVU).
• The interface module has terminals blocks to allow a second pair of wires to be looped through to supply the downstream connected elements with LSN power.
• For a fire system operation according to EN 54‐2,the interface modules used for the activation of fire protection equipment and whose outputs are not monitored, must be installed directly next to or within the device which shall be activated.

Technical specifications

Electrical
LSN
• LSN input voltage 15 V DC to 33 V DC
• Max. current consumption
from LSN
1.9 mA
Output
• Max. switchable voltage of
semi-conductor output
30 V DC
• Max. switchable output
current
700 mA (depending on power supply)
• External power supply 5 V DC to 30 V DC
Input
Line monitoring with EOL
• EOL resistor Nominal 3.9 kΩ
• Overall line resistance RΣ
with RΣ = RL/1 + RL/2 + REOL
• Standby: 1500 Ω to 5500 Ω
• Short circuit: < 800 Ω
• Line interruption: > 85000 Ω
Contact monitoring
• Max. current strength
(current pulse)
8 mA
Minimum activation time of the in-put 3.2 s
Mechanical  
Connections
• FLM-420-O1I1-E 14 screw terminals
• FLM-420-O1I1-D 12 screw terminals
Permissible wire diameter
• FLM-420-O1I1-E 0.6 mm2 to 2.0 mm2
• FLM-420-O1I1-D 0.6 mm2 to 3.3 mm2
Address setting
• FLM-420-O1I1-E 8 DIP switches
• FLM-420-O1I1-D 3 rotary switches
Housing material
• FLM-420-O1I1-E ABS/PC blend
• FLM-420-O1I1-D incl.
adapter
PPO (Noryl)
Housing color
• FLM-420-O1I1-E Signal white, RAL 9003
• FLM-420-O1I1-D incl.
adapter
Gray white, similar to RAL 9002
Dimensions
• FLM-420-O1I1-E Approx. 50 mm x 22 mm (Ø x H)
• FLM-420-O1I1-D incl.
adapter
Approx. 110 x 110 x 48 mm
(W x H x D)
Weight Without/with packing
• FLM-420-O1I1-E Approx. 35 g / 170 g
• FLM-420-O1I1-D Approx. 95 g / 390 g
Environmental conditions
Permissible operating temperat-
ure
-20 °C to +65 °C
Permissible storage temperature -25 °C to +80 °C
Permissible rel. humidity < 96% (non-condensing)
Classes of equipment as per
IEC 60950
Class III equipment
Protection class as per IEC 60529 IP 30
System limiting values
Maximum cable length input  
• FLM-420-O1I1-D 3 m
• FLM-420-O1I1-E Flush mounted
Maximum cable length output  
• FLM-420-O1I1-D 3 m
• FLM-420-O1I1-E Flush mounted
Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping Policy:
1. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
Write Your Own Review
You're reviewing:Output / Input Interface Module | FLM‑420‑O1I1-E | BOSCH
Your Rating
WA button WA button