NX-TS NX-series Temperature Input Unit/ Specifica Omron
₹39,483.00 ₹46,589.94
In stock
Product Name | NX-TS NX-series Temperature Input Unit/ Specifica Omron |
---|---|
Brand | Omron |
Test Certificate | No |
Model | NX-TS3101 |
COUNTRY OF MANUFACTURE | India |
HSN Code | 85389000 |
Category | Temperature or PID Controllers |
Product Code | EXP-0008 |
In Stock ( 1 Units )
Temperature Input Unit (Thermocouple Input type) 2 points NX-TS3101 | |||
Unit name | Temperature Input Unit (thermocouple input type) |
Model | NX-TS3101 |
Number of points | 4 points | External connection terminals |
Screwless clamping terminal block (16 terminals x 2) |
I/O refreshing method |
Free-Run refreshing | ||
Indicator
|
TS indicator
|
Temperature sensor | K, J, T, E, L, U, N, R, S, B, WRe5-26, PLII |
Input conversion range | ±20°C of the input range | ||
Absolute maximum rating |
±130 mV | ||
Input impedance | 20 kΩ min. | ||
Resolution | 0.1°C max. *1 | ||
Reference accuracy | *2 | ||
Temperature coefficient |
*2 | ||
Cold junction compensation error |
±1.2°C *3 *4 | ||
Input disconnection detection current |
Approx. 0.1μA | ||
Warm-up period | 30 minutes | Conversion time | 250 ms/Unit |
Dimensions | 24 (W) x 100 (H) x 71 (D) | Isolation method | Between the input and the NX bus: Power = Transformer, Signal = Photocoupler Between inputs: Power = Transformer, Signal = Photocoupler |
Insulation resistance |
20 MΩ min. between isolated circuits (at 100 VDC) |
Dielectric strength | 510 VAC between isolated circuits for 1 minute at a leakage current of 5 mA max. |
I/O power supply method |
No supply | Current capacity of I/O power supply terminal |
Without I/O power supply terminals |
NX Unit power consumption |
• Connected to a CPU Unit or Communication Control Unit 1.75 W max. • Connected to a Communi- cations Coupler Unit 1.30 W max. |
Current consumption from I/O power supply |
No consumption |
Weight | 140 g max. | ||
Installation orientation and restrictions |
Installation orientation: • Connected to a CPU Unit or Communication Control Unit: Possible in upright installation. • Connected to a Communications Coupler Unit: Possible in 6 orientations. Restrictions: The cold junction compensation error is restricted according to the installation orientation and the power consumption of adjacent Units. Refer to Cold Junction Compensation Error Specifications for Units That Take a Thermocouple Input Type. |
||
Terminal connection diagram |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping Policy: |
1. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
Write Your Own Review