MCP (Addressable Single Action Manual Pull Station with Isolation) - HMS-S - Siemens

₹5,500.00 ₹6,490.00
Out of stock
More Information
Product NameMCP (Addressable Single Action Manual Pull Station with Isolation) - HMS-S - Siemens
Weight1.000000
COUNTRY OF MANUFACTUREIndia
BrandSiemens
HSN Code8531
System TypeCONVENTIONAL
ModelHMS-S
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryAlarm System, Fire Safety, Manual Call points
Product CodeCPK-0168
Freight Extra (Godown Delivery)
Out Of Stock

Architect & Engineer Specifications

Durable metal design
Shock and vibration resistant
Single-action (Model HMS-S | -SZ) and double-action (Model HMS-D | -DZ) stations
Pull-down lever is down, until manually reset
    Reset with Allen Key
    No break rods necessary
Custom microcomputer-chip technology
Polarity insensitive via SureWireTM technology
Dynamic supervision to the fire-alarm control panel (FACP)
Device Programmer Unit (Model DPU) programs and verifies address and tests functionality of each device
Electronic-address programming (EEPROM) is easier, as well as more efficient, dependable
Surface or semi-flush installation
Two-wire
Americans with Disabilities Act (ADA) Compliant
UL Listed
USCG (161.002/60/0),
FM (#3015946 & 3052621),
   CSFM (#7150-0067:0036)
NYC Fire Dept. (#202-12E, Vol. 1) Approved

Product Overview

The Siemens intelligent manual fire-alarm boxes (Models HMS-S | HMS-SZ and HMS-D | HMS-DZ) provide the most advanced method of address programming and supervision

Each Model HMS-series manual box achieves the state of an ‘intelligent-initiating device’ by incorporating custom microcomputer-chip technology with sophisticated, bi-directional communication capabilities with the panel, which include Siemens Modular, as well as Siemens 50-point, 252-point and 504-point addressable FACPs.

The Model HMS- series manual fire-alarm boxes are also included in US Coast Guard (USCG) approval for use in marine and other harsh environments, when used with the Siemens 252-point and 504-point USCG approved addressable system

Specifications

Models HMS-S | HMS-SZ and HMS-D | HMS-DZ are constructed of durable, molded polycarbonate material that is matte finished in red with raised white lettering. The housing accommodates a ‘pull-down’ lever, which ─ when operated ─ locks into position; indicating the firealarm box has been activated.

The pull-down lever remains down / in the ‘locked’ position, until the fire-alarm box is manually reset. The manual fire alarm box can only be reset by opening the hinged housing cover with an Allen key; followed by closing and locking the cover. Models HMS-S | -SZ and HMS-D | -DZ operate with Siemens ─ Fire Safety FACPs. The microcomputer chip to the manual fire-alarm box has the capacity of storing ─ in memory ─ identification and important operating-status data

Models HMS-S | -SZ and HMS-D | -DZ are fitted with screw terminals for connection to an addressable circuit, and can be either surface or semi-flush mounted.

The Model HMS-series manual fire-alarm boxes derive their power, communicate information and receive commands over a single pair of wires. Each box is compatible on the same circuit with all Model `H’-series detectors, interfaces or addressable, conventional zone modules.

Device / Programmer Tester – Model DPU

Innovative technology from Siemens ─ Fire Safety also allows all Model HMS-series intelligent manual fire-alarm boxes to be programmed via the Device Programmer / Test Unit (Model DPU). The programmer / tester is a compact, portable and menudriven accessory that makes programming and testing of a manual fire-alarm box device faster, easier and more dependable than previous methods.

Model DPU eliminates the need for mechanical-addressing mechanisms of a device because Model DPU electronically sets the address of the manual fire-alarm box into its microcomputer chip, non-volatile memory. Therefore, vibration, corrosion and other conditions -- which can compromise the functionality of mechanical-addressing mechanisms – are no longer an issue.

Technical Data

ELECTRICAL
Current Draw
(Active or Standby)
0.9mA

 

INDOOR / DRY CONDITIONS
Operating
Temperature Range
32° ─ 100°F
(0° ─ 38°C)
Operating
Humidity Range
0 ─ 93%,
non-condensing

 

Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:MCP (Addressable Single Action Manual Pull Station with Isolation) - HMS-S - Siemens
Your Rating
WA button WA button