Fire Alarm Hooter | Multi Candela Horn | ZH-MC-R | Siemens

₹5,300.00 ₹6,254.00
In stock
More Information
Product NameFire Alarm Hooter | Multi Candela Horn | ZH-MC-R | Siemens
Weight1.000000
COUNTRY OF MANUFACTUREIndia
BrandSiemens
HSN Code8531
System TypeCONVENTIONAL
ModelZH-MC-R
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryAlarm System, Fire Safety, Sounder Strobes
Product CodeCPK-0029
Freight Extra (Godown Delivery)
In Stock ( 100 Units )

Product Overview

•  Strobes can be synchronized using the Siemens DSC sync modules, the     Siemens 50-point, 252-point and 504-point addressable fire alarm control panels (FACPs), as well as with:
    • FireFinder® XLS and MXL® FACPs
    • PAD-3 or PAD-4TM NAC Extenders with built-in sync protocol

• Selectable Continuous Horn or Temporal (Code-3) Tones with 90 or 95 dBA
   selectable setting (Series ‘ZH’)

• Ceiling-mount models feature field-selectable Candela settings of  15/30         /75/95cd and 115/177cd

• Wall-mount models feature field-selectable Candela settings of          15/30/75/110cd and 135/185cd

• Base plate is protected by a disposable cover, and the appliances canquickly snap onto the base after the walls are painted

• Strobes produce one (1) flash per second

• ``Special Applications” listed with Siemens panels

• EZ Mount Universal Mounting Plate (Model ZB Series)  uses single plate
   for ceiling and wall mount installations

• EZ Mount design  with separate base plate  provides ability to pre-wire the base and test the circuit wiring before the walls are covered

• UL Listed & ULC Listed, FM (#3028994) Approved;
  CSFM Approved (Series ‘ZH’: #7125-0067:0248 –> Fire Alarm Devices For    The Hearing Impaired)
  CSFM Approved (Series ‘ZR’: #7125-0067:0252 –> Fire Alarm Devices For      The Hearing Impaired)

• ADA / NFPA compliant

Specifications

• Audible/Visual notification appliances are listed for indoor use only

• Appliances are listed under UL Standard 1971 (Standard for Safety       Signaling Devices for Hearing Impaired) and UL Standard 464 (Fire Protective Signaling)

• Appliances use a universal back plate, which allows mounting to a single-gang,double-gang, 4-inch-square (10.2 cm.), 4”-octal (10.2 cm.), or a 3-1/2” (8.9 cm.) octal backbox

• Two-wire configurations allows capability for directly connecting appliances to the mounting back plate

• Continuity check will occur for entire NAC circuit prior to attaching any audible / visual-notification appliances

• A cover fits over the mounting plate for protection to dust and other outside elements
    •  Cover is easily removed when the appliance is installed over the back plate

• Removal of an appliance will result in a Trouble condition by the Siemens Fire Alarm Control Panel (FACP)

Specifications – (continued)

Strobes and Audible Strobe Combinations

• Strobe appliances produce a minimum flash rate of 60 flashes per minute
(one [1] flash per second) over the Regulated Input Voltage Range, and
incorporate a Xenon flashtube enclosed in a rugged Lexan® lens

• Strobes are available with two (2) or four (4) field-selectable settings
in one (1) unit, and are rated – per UL 1971 – for up to:
   • 15/30/75/110cd for wall mounted
   • 135/185cd for wall mounted
   • 15/30/75/95cd for ceiling mounted
   • 115/177cd for ceiling mounted

•  Strobes operate over an extended temperature range of 32°F to 120°F
(0°C to 49°C), and be listed for maximum humidity of 95% RH

• Strobe inputs are polarized for compatibility with standard reverse-polarity
supervision of circuit wiring by a Siemens FACP

Audible and Audible / Strobe Combinations
•  Horns and horn / strobes are listed for Indoor use under UL Standard 464
•  Horns are able to produce continuous synchronized output or a
   Temporal Code-3 synchronized output
•  Horns have at least two (2) sound-level settings of 90 and 95 dBA

Synchronization Modules
•  The strobe portion, when synchronization is required, is compatible with the Siemens DSC sync modules; the Siemens 50-point, 252-point and 504-point addressable FACPs, as well as with:
  •  FireFinder® XLS and MXL® FACPs
  • PAD-3 or PAD-4TM NAC Extenders with built-in sync protocol

• The strobes will not drift out of synchronization at any time during operation

• Audibles and strobes are able to synchronize on a two-wire circuit with the capability to silence the audible, if required

• Strobes revert to a non-synchronized flash-rate, if the sync module or
power supply should fail to operate (i.e. – contacts remain closed)

• All notification appliances are listed for Special Applications:

Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second,
and ADA Guidelines specify a flash rate of 1-to-3 flashes per second

• All candela ratings represent minimum-effective Strobe intensity, based on    UL Standard 1971
• Series ZH Strobe products are listed under UL Standards 1971 and 464 for     indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%)

• Series ZH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only)

   ZH Horn: Wall and Ceiling Mount

Operating Voltage (Special Application)
Per UL 464
  Input Voltage Low* High*
DC 16.0 – 33.0VDC 0.018 0.044
FWR 16.0 – 33.0VRMS 0.045 0.075

 ZH Horn / Strobe Series: Wall Mount

Current Ratings (AMPs)

MAXIMUM RMS Current – with High dBA Setting

 

Input Voltage

15cd 30cd 75cd 110cd 135cd 185cd
DC 16.0 – 33.0VDC 0.078 0.113 0.195 0.259 0.371 0.506C
FWR 16.0 – 33.0VRMS 0.141 0.200 0.302 0.406 0.521 0.722

Current Ratings (AMPs)

MAXIMUM RMS Current – with Low dBA Setting

  Input Voltage 15cd 30cd 30cd 95cd 135cd 185cd
DC 16.0 – 33.0VDC 0.070 0.107 0.188 0.246 0.324 0.455
FWR 16.0 – 33.0VRMS 0.123 0.179 0.290 0.391 0.497 0.699

ZH Horn / Strobe Series: Ceiling Mount

Current Ratings (AMPs)

MAXIMUM RMS Current – with High dBA Setting

  Input Voltage 15cd 30cd 75cd 95cd 115cd 177cd
DC 16.0 – 33.0VDC 0.087 0.131 0.222 0.292 0.371 0.506
FWR 16.0 – 33.0VRMS 0.149 0.216 0.331 0.436 0.521 0.722

Current Ratings (AMPs)

MAXIMUM RMS Current – with Low dBA Setting

  Input Voltage 15cd 30cd 75cd 95cd 115cd 177cd
DC 16.0 – 33.0VDC 0.075 0.121 0.213 0.277 0.324 0.455
FWR 16.0 – 33.0VRMS 0.131 0.195 0.319 0.421 0.497 0.699

ZH and ZH-MC Series: Wall and Ceiling Mount

      dBA Sound Output
        Reverberant Per UL 464
Description

Volume 16.0 VDC 24.0 VDC 33.0 VDC
Continuous
Horn
Low 77 81 83


High 83 87 90
Code 3 Horn
(or March Time)**
Low 72 76 79
    dBA Sound Output
                    Reverberant Per UL 464
Description Volume 20.0 VDC  24.0 VDC 31.0 VDC
Continuous
Horn
Low 88 90 91
  High 93 95 96
Code 3 Horn
(or March Time)**
Low 88 90 91
  High 93 95 96

Technical Data – (continued)
Notes:

1. Strobes will produce 1 flash per second over the Input Voltage range.

2. These horn/strobe models are UL Listed to operate over a Voltage Range Limit from 16.0VDC to 33.0VDC for 24VDC applications using filtered DC or unfiltered Full-Wave-Rectified (FWR) input voltage.
3. All models are UL Listed for indoor ceiling use with a temperature range of    +0oC to +49oC (+32oF to +120oF) and maximum humidity of 93% +/- 2% RH. The effect of shipping and storage temperatures will not adversely affect the performance of the appliance
when stored in original cartons, and is not subjected to either misuse or improper handling of shipment.

 

 

Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping Policy:
1. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
Write Your Own Review
You're reviewing:Fire Alarm Hooter | Multi Candela Horn | ZH-MC-R | Siemens
Your Rating
WA button WA button