Double Action Manual Call Point Indoor, Red | FMC-210-DM-G-R | BOSCH
Product Name | Double Action Manual Call Point Indoor, Red | FMC-210-DM-G-R | BOSCH |
---|---|
Weight | 1.000000 |
COUNTRY OF MANUFACTURE | India |
Brand | Bosch |
HSN Code | 85318000 |
System Type | CONVENTIONAL |
Model | FMC-210-DM-G-R |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Alarm System, Fire Safety, Manual Call points |
Product Code | CPK-0059 |
• FMC‐210‐DM Double Action Call Points
• Adjustment after alarm triggering
• Individual identification thanks to automatic or manual detector addressing
• Indicator LED for alarm or for inspection evaluation
• Query routines with evaluation and multiple transmission
• Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
The FMC-210-DM Double-action Call Points are used for manual triggering, and can be used in the Local SecurityNetwork LSN and LSN improved. Form H
Manual Call Points are designed for outdoor deployment, form G Manual Call Points are designed for indoor deployment.
In the event of an alarm, the glass pane (2) is broken first, then the manual call point (3) is pressed hard.This activates the microswitch for alarm triggering and the indicator LED (4) blinks. A mechanism holds the pressed call point down.
The manual call point can be reset with the reset lever (5) or by closing the door of the manual call point (1).The indicator LED (4) goes out.
This does not reset the alarm on the fire panel.
Individual call point identification with display of the call point address on the fire panel ensures the quick location of the triggered call point.
Variants
The designs of the manual call points for outdoor and indoor use are identical. The manual call points for indoor use (form G) are available in red, blue, yellow,and green. The manual call points for outdoor use (form H) are available in red and blue. Form H manual call points are equipped with an
especially resistant PC board layered with parylene.
Notice : The key must be ordered separately.
Improved LSN features
The manual call points offer all the features of the improved LSN technology:
• Flexible network structures, including T-tapping without additional elements
• Up to 254 LSN improved elements per loop or stub line
• Automatic or manual detector addressing selectable via rotary switch, in each case with or without auto-detection
• Shielded and unshielded cables can be used
• Cable length up to 3000 m (with LSN 1500 Amodule)
• Downwards compatibility to existing LSN systems and control panels
Certifications and approvals
Type Number | Complies with |
FMC‐210‐DM‐G‐R | EN 54-11:2001/A1:2005, EN 54-17:2005 |
FMC‐210‐DM‐ H‐R |
EN 54-11:2001/A1:2005, EN 54-17:2005 |
FMC‐210‐DM‐ G‐Y |
EN 12094-3:2003, EN 54-17:2005 |
Region | Regulatory compliance/quality marks | |
Germany | VdS |
G 206098 FMC-210_DM-G-R/- H-R_G206098 |
VdS | G 206099 FMC-210_DM-G-Y_G206099 | |
Europe | CE | FMC-210-DM-G-B/-H-B/-SM-G-B |
CE | FMC-210_DM-G-R/-H-R/-SM-G-R | |
CE | FMC-210-DM-G-Y / EST-G-B | |
CPD | 0786-CPD-20293 FMC-210-DM-G/H-R | |
CPD | 0786-CPD-20293 FMC-210-DM-G/H-R | |
Poland | CNB OP |
1505/2013 FMC-210 DM-G-R, FMC-210 DM-H-R |
Ukraine | MOE | UA1.016.0070338-11 FMC-210-DM-G-R_FMC-210- DM-H-R_FMC-210-DM-G-R-A |
Slovakia | EVPÚ |
SK08-ZSV-0071 FMC-210-DM, FMC-210-EST |
Installation/configuration notes
• The device must be mounted visibly along escape and rescue routes (e.g. exits, passageways,stairwells) and be easily accessible.
• An installation height of 1400 mm ±200 mm,measured from the middle of the device to the floor, must be maintained.
• The device must be adequately illuminated by sunlight or another light source (including emergency lighting if present).
• The maximum number of LSN elements that may be connected depends on their current consumption from the LSN data line. The limit values should be
taken from the product information supplied with the fire panel used.
• Additional norms, guidelines, and planning recommendations with respect to installation location, etc. must be taken into account (see fire detector manual).
• The regulations of the local fire services must be observed.
Installation
• The cable duct can be surface-mounted or flush-mounted.
• Installation in fire hose cabinets is possible in three
ways:
1 ca. 40 mm
2 14 mm
3 min. 30 mm
Technical specifications
Electrical | |
Operating voltage (VDC) | 24 (15 to 33) |
Current consumption (mA) | 0.26 |
Mechanics | |
Dimensions W x H x D (mm) | 135 x 135 x 40 |
Housing material | Plastic ASA |
Colors |
Red RAL 3001 Green close to RAL |
Weight (g) | Approx. 235 |
Environmental | |
Degree of protection (IEC 60529) Form H |
IP 54 |
Degree of protection (IEC 60529) Form G |
IP 52 |
FMC‐210‐DM‐G‐R | EN 54-11 |
FMC‐210‐DM‐H‐R | EN 54-11 |
FMC‐210‐DM‐G‐Y | EN 12094-3 |
Operating temperature Form H (°C) |
-25 to 70 |
Operating temperature Form G (°C) |
-10 to 55 |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping & Delivery Policy: |
1. | 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
4. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |