Door Reader Interface Sub or Slave controller, Single Door, Vertex V100 HID
Product Name | Door Reader Interface Sub or Slave controller, Single Door, Vertex V100 HID |
---|---|
Weight | 1.000000 |
Brand | HID |
Test Certificate | No |
COUNTRY OF MANUFACTURE | India |
Model | HID-ACS-V100 |
HSN Code | 84719010 |
Warranty | 6 Months |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Fire Safety, Access Control System, Biometric, Smart Cards |
Product Code | CPK-0005 |
Door Reader Interface Sub or Slave controller, Single Door, Vertex V100 HID
ACCESS CONTROL PROCESSING FOR TWO READERS/ TWO DOORS • 70100
• Reports supervised inputs.
• Connects to the V1000 via RS-485.
• Receives and processes real-time commands from the V1000.
• Reports all activity to the V1000.
• Attractive polycarbonate enclosure protects components
from damage.
• All connections and indicators are fully identified by silk-screened
nomenclature on the cover.
• Processes off-line access control decisions based on facility code.
• UL® 294 and UL® 1076 recognized components.
The HID VertXTM products provide a complete and fully featured hardware/firmware infrastructure for access control software host
systems. The V100 Door/Reader interface connects two access control card readers via Wiegand or Clock- and-Data interface, controlling either one or two doors. The V100 features on-board flash memory, enabling program updates to be downloaded via the network. The V100 connectsto the V1000 through a high speed RS-485 network. The V1000, in turn,
communicates with the system host via industry-standard TCP/IP protocol over 10/100 Mbps Ethernet or the Internet. This architecture minimizes the impact on corporate LANs by using only one TCP/IP address for every 32 interfaces and by handling low-level transactions on the RS-485 network.
MOUNTING :
Mount to any wall surface, using four screws. For UL® compliance, one or more interfaces can be mounted inside a locking customer- supplied NEMA-4 rated enclosure with:
• DC supply with battery back-up
• Enclosure tamper switch
• All connections made through conduit
The unit should be installed indoors, inside a secure area, such as in an IT or
telecommunications room, utility closet, or on a wall above a suspended ceiling.
VISUAL INDICATORS : Communications LED flashes green for “transmit to host” and red for “receive from host.” Power LED indicates that sufficient
DC voltage is being provided to the unit.
EASILY INTERFACED : Quick-disconnect screw terminal connectors
• Rotary address switch (0–15)
• Inputs for:
• 2 readers
• 2 door monitor switches,
• 2 Request-to-Exit switches
• AC Fail Monitor*
• Battery Fail Monitor*
• Enclosure Tamper*
*Can be configured as a general purpose input
NON-LATCHING RELAY OUTPUTS (RATED 2A @ 30 VDC):
• 2 door strikes (configurable)
• 2 auxiliary devices: door held/forced
alarm, alarm shunt, host off-line
(comms down), or general purpose
LOCAL PROCESSING :
• Alarm shunt and strike relay timing and latching functions
• Access control decisions based on facility code (degraded mode)
• Basic input/output linking
• LED/beeper control during card + PIN, scheduled unlock, and other
transactions
MICROCONTROLLER :
WARRANTY : Warranted against defects in materials and workmanship for 18 months (see complete warranty policy for details).
PART NUMBERS : Base Part Number: 70100
SPECIFICATIONS :
Dimensions | 5.8" W x 4.825" H x 1.275" D (147.32 mm x 122.55 mm x 32.38 mm) |
Weight | 12.4 oz (.35 kg) |
Enclosure Material | UL94 Polycarbonate |
Power Supply Requirements | 60 mA @ 9–18 VDC (with no readers connected). Recommended: Supervised linear power supply with battery backup, input surge protection, and AC fail and battery low contact outputs. When VertXTM is supplying power to readers, the requirements are 600 mA @ 9–18 VDC. The V100 can supply 500 mA to two readers. Separate supervised DC supplies with battery back-up recommended for door locking or relay-activated devices, or for HID MaxiProx® readers. |
Operating Environment | Indoors, or customer-supplied NEMA-4 rated enclosure |
Operating Temperature | 32° to 122° F (0° to 50° C) |
Operating Humidity | 5% to 95% relative, non-condensing |
Storage Temperature | -67° to 185° F (-55° to 85° C) |
Communications Ports | RS-485 — two wire. Two SIA standard Wiegand/Clock-and-Data ports |
Certifications | UL® 294 and UL® 1076 Recognized Component for the US, CSA 205 for Canada, FCC Class A Verification, EMC for Canada, EU (CE Mark), Australia (C-Tick Mark), New Zealand, Japan, EN 50130-4 Access Control Systems Immunity for the EU (CE Mark) |
Cable Distance | RS-485 — 4000 feet (1220 m) to host using Belden 3105A, 22 AWG twisted pair, shielded 100Ω cable; Wiegand — 500 feet (150 m) to reader using ALPHA 1299C 22 AWG, 9-conductor, stranded, overall shield (fewer conductors needed if all control lines are not used); Input Circuits — 500 feet (150 m), 2-conductor, shielded, using ALPHA 1292C (22 AWG) or Alpha 2421C (18 AWG); Output Circuits — 500 feet (150 m), 2-conductor, using ALPHA 1172C (22 AWG) or Alpha 1897C (18 AWG); minimum wire gauge depends on cable length and current requirements. |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping Policy: |
1. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |