Conventional zone module for FPA-1000 | FLM-325-CZM4 | BOSCH

₹3,360.00 ₹3,964.80
In stock
More Information
Product NameConventional zone module for FPA-1000 | FLM-325-CZM4 | BOSCH
Weight1.000000
COUNTRY OF MANUFACTUREIndia
BrandBosch
HSN Code85319090
System TypeCONVENTIONAL
Model325‑CZM4
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryAlarm System, Fire Safety, Control Module
Product CodeCPK-0087
Freight Extra (Godown Delivery)
In Stock ( 100 Units )

Provides a zone of up to 25 conventional smoke detectors (depending on detector type)
Supervises auxiliary power supply for conventional detectors
Compatible with Class B (Style B) or Class A (Style D)
Module address programming with the D5070 Analog Device Programmer between 1 and 127
Bi‐colored LED provides module status

The FLM‐325‐CZM4 Conventional Zone Module enables the FPA‐1000 Analog Addressable Fire Panels
to interface and monitor up to 25 conventional devices depending on the device type such as two-wire smoke detectors or pull stations.

The module requires an auxiliary input voltage to provide power for the detector zone. It supervises the
power supply as well as the entire zone of devices. Status conditions are reported as normal, open or
short.

The module offers fixed threshold levels for open and short that can not be changed. It fits into a standard 4‐inch square or double‐gang electrical back box.

Functions

Address programming
Each module is addressed through the D5070 Analog Device Programmer and transmits the status of one zone of devices back to the panel.
Status display
The module has a bi‐colored LED that flashes every time the module is polled and can be switched on
steady when the module goes into active condition.

Certifications and approvals

Region Certification
USA UL UOXX: Control Unit Accessories, System (ANSI/UL 864)
  CSFM see our website
  FDNYCoA #6101

Installation/configuration notes

Compatible Products
The following products are compatible with the FLM‐325‐CZM4 Conventional Zone Module:

Category Product ID Product Description
Fire Panels FPA‐1000 Analog Addressable Fire Panels
Two‐wire
Detectors
D2541 Fixed-temperature (135°F
[57°C]) Heat Detector Head
  D2551 Fixed-temperature (190°F
[88°C]) Heat Detector Head
  D256A2 Fixed-temperature (135°F
[57°C]), Rate-of-Rise Heat
Detector Head
  D257A2 Fixed-temperature (190°F
[88°C]), Rate-of-Rise Heat
Detector Head
  D265AW2 Photoelectric Smoke Detector Head
  D281A2 Ionization Smoke Detector
  D282A2 24 VDC Smoke Detector Head
  D283A2 24 VDC Smoke/Heat Detector Head

1
Requires D253 Two‐wire Detector Base (24 VDC)
2
Requires D280A Two‐wire Detector Base (24 VDC)

Parts included

Quant. Component
1 FLM‐325‐CZM4 Conventional Zone Module
1 EOL resistor 4.7 kΩ
1 Wall plate
1 Literature pack

Technical specifications

Electrical
Operating Voltage 17 VDC to 41 VDC
Current Consumption
• Standby 0.4 mA
• Active (from auxiliary power supply 60 mA
• Data transmission 22 mA ±20 %
Resistance
• EOL 4.7 kΩ
• Alarm Threshold < 1.5 kΩ
Mechanical
Dimensions (H x W x D) 4.7 in. x 4.2 in. x 1.4 in. (11.9 cm x 10.7 cm x 3.6 cm)
Bicolored LED Red and green
Environmental
Operating Temperature +32°F to +120°F (0°C to +49°C)
Relative Humidity 90 %, non‐condensing

 

Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping Policy:
1. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
Write Your Own Review
You're reviewing:Conventional zone module for FPA-1000 | FLM-325-CZM4 | BOSCH
Your Rating
WA button WA button