Conventional Sounder cum strobe | Wall Mounted | SLHSWR-F | Siemens
Product Name | Conventional Sounder cum strobe | Wall Mounted | SLHSWR-F | Siemens |
---|---|
Weight | 1.000000 |
COUNTRY OF MANUFACTURE | India |
Brand | Siemens |
HSN Code | 85311090 |
System Type | CONVENTIONAL |
Model | SLHSWR-F |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Alarm System, Fire Safety, Sounder Strobes |
Product Code | CPK-0042 |
Architect & Engineer Specifications
Sophisticated series of notification appliances that meets fire-industry codes
and regulations for commercial-building applications
• Compatible with the Siemens 50-point, 252-point and 504-point addressable fire alarm control panels (FACPs), and with:
- Siemens Modular FACPs
- Siemens PAD-series of NAC extenders
- FireFinder® XLS / XLSV FACPs
- Siemens dual-sync control (DSC) modules
• Innovative LED strobe technology provides an energy-efficient means for a
significantly reduced current draw
- Capability to have existing Xenon and new LED strobes in the same field-of-view
- Fewer power supplies required, smaller wire gage, reduced wire runs
• Straightforward installation coupled with compact, modern design
- No visible mounting screws
- Manual (index finger) slide-setting adjustor
- Four (4) field-selectable settings in one (1) device: 15cd | 30cd | 75cd |110cd
• Faceplates ship in four (4) distinctive types:
- ‘FIRE’ | ‘ALERT’ | ‘AGENT’ | (blank)
• Two (2) audible settings in each notification appliancev
- Temporal or steady horn output
- High or Low setting
• UL (2034 | 1971 | 464) and ULC Listed (ULC-S525 | - S526) ; CS
• ADA | NFPA | FCC | ANSI | OSHA compliant
Product Overview
Formed as the `SL’-series, Siemens is now offering horns, strobes, and horn-strobes with LED based strobes to its notification-appliances portfolio. With the `SL’-series, Siemens offers a full range of products with low and high candela settings that makes these sophisticated notification appliances ideal for new installs and retrofit applications.
Innovative light-emitting diode (LED) strobe technology provides an energy-efficient means for a significantly reduced current draw.The strobe portion of these appliances meets the 20 millisecond light-pulse-duration requirements of the 2016 edition of NFPA 72. This feature allows existing Xenon and the new LED devices to be used in the same field-of-view.
In a single device, the `SL’-series can provide alarm-signaling tones for dual
applications. All strobe models in the series feature multi-Candela settings (15 | 30 | 75 | 110cd) on a single appliance.
Additionally, there are two (2) modes of operation for the audible portion of these notification appliances:
• T3 (coded)
• Continuous
The `SL’-series of horns, strobes and horn-strobes devices are produced in a sleek,modern design. Its single-gang form factor provides high-quality energy efficiency in an aesthetically pleasing, low-profile design that is consistent to the look of the interior composition of the building application.
The `SL’-series is apt for indoor wall-mount applications. The Model `SLH’-series horn appliances work in either 12V or 24VDC, whereas the Series `SLSW’ and `SLHSW’ strobe and horn-strobe devices are specifically for 24V operation.
Specifications
In terms of composition and functionality, Models `SLHW’-series, `SLSW’-series, and `SLHSW’-series provide added value to the installer for the types of applications for operation:
• Compact | sleek | low-profile design
• Comprehensive feature list
• Convenient mounting options
• Easy-to-adjust selection-slider switch for Candela settings
− No tools required for setting changes
− Multi-level settings: 15cd | 30cd | 75cd | 110cd
• High and Low audible outputs
• Reduced current draw, via cutting-edge LED technology
The LED portions of the Siemens `SL’-series of strobes and horn-strobes meet the 20 millisecond light-pulse-duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, existing Xenon as well as the new LED-technology devices can now be in the same field-of-view.
The horn, strobe and horn-strobes in this Siemens `SL’-series of notification appliances have received UL / ULC Listed status by attaining compatible testing standards with all of the Siemens fire-alarm control panels (FACPs) and accessories that have been determined to be aligned with existing Siemens strobe-based appliances.
This would include the following existing model-types: `CH’|`HS’|`MTH’ |`S-HQ’|`SA’|`SE’|`SEF’|`SET’ |`ST’ |`STH’ |`ZR’ and `ZH’ Series notification appliances. The regulatory listing also includes the capability for installing the
Siemens `SL’-series LED-based strobes in the same notification zone and field-of-view with any existing Siemens Notification Appliance Xenon-based strobes.
All types of these horns, strobes and horn-strobes are UL Listed (for indoor use under Standard 1971 and464), as well as ULC-S525|ULC-S526 Listed. The Siemens `SL’-series sounder-strobes also have ADA | RoHS and ICES approval.
Technical Data
Wall-Mount | Horn-Strobes | Output Current Draw
Current Ratings (HIGH dB | in Amps) 16.0 – 33.0VDC |
|||||
MODEL `SLHSW’ SERIES: |
Setting | 15cd | 30cd | 75cd | 110cd |
Code | 0.034 | 0.046 | 0.105 | 0.214 | |
Continuous | 0.042 | 0.052 | 0.110 | 0.217 |
Wall-Mount | Horn-Strobes | Output Current Draw
Current Ratings (LOW dB | in Amps) 16.0 – 33.0VDC |
|||||
MODEL `SLHSW’ SERIES: |
Setting | 15cd | 30cd | 75cd | 110cd |
Code 3 | 0.032 | 0.042 | 0.102 | 0.213 | |
Continuous | 0.036 | 0.044 | 0.104 | 0.216 |
GENERAL NOTES:
1. Strobes are designed to flash at 1-flash-per-second minimum over their “ Regulated Voltage Range.”
2. NFPA-72 specifies a flash rate of 1-to-2 flashes-per-second, and guidelines for the Americans with Disabilities Act (ADA)
specify a flash rate of 1-to-3 flashes-per-second.
3. All Candela ratings represent minimum effective Strobe intensity based on UL 1971.
Technical Data
…General Properties
OPERATING TEMPERATURE: |
- 32°F (0°C) to 122°F (50°C) - for indoor-applications’ use only |
RELATIVE HUMIDITY: | 93%, maximum |
OPERATING VOLTAGE RANGES: |
- 12 VDC / VFWR - 8 - 17.5 VDC / VFWR; - 24 VDC / VFWR - 16 - 33 VDC/VFWR (12 VDC for Model SLH Wonly) |
STROBE OUTPUT RATING: |
- UL 1971, ULC-S526 - Field-selectable 15cd | 30cd | 75cd | 110cd Candela outputs |
STROBE FLASH RATE: | Strobes are designed to flash at one-flash-per-second |
STROBE SYNCRONIZATION: |
- all Siemens addressable panels - Siemens PAD-series NAC extenders - Siemens dual-sync (DSC) modules, which provide the unique Siemens proprietary synchronization protocol |
TEMPORAL PATTERN: |
- Continuous - Code 3 (1/2 second on, 1/2 second off; then 1/2 second on, 1/2 second off; followed by 1/2 second on, 1-1/2 second off and repeat) NOTES: The Code 3 pattern is specified by ANSI and NFPA 72 for Standard Emergency Evacuation Signaling. |
Physical Properties
MODEL `SL’-series | |||
MATERIAL: | - White-or-red textured, ultraviolet (UV) stabilized, colored impregnated engineered plastic - Exceeds 94V-0 UL flammability rating |
||
WEIGHT: | 0.35 Lbs. (0.16 Kg.) | ||
LENS TYPE: | LED strobe situated in a rugged Lexan lens | ||
DIMENSIONS: |
|
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping & Delivery Policy: |
1. | 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
4. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |