Continuous Ambient Air Quality Monitoring Station EE-CAAQMS-05 (Sox, Nox, Co,Pm 10, Pm 2.5)

₹4,000,000.00 ₹4,720,000.00
In stock
More Information
Product NameContinuous Ambient Air Quality Monitoring Station EE-CAAQMS-05 (Sox, Nox, Co,Pm 10, Pm 2.5)
Weight1.000000
Test CertificateNo
COUNTRY OF MANUFACTUREIndia
ModelEE-CAAQMS-05
HSN Code9027
Shipping time (business days)7
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryMonitoring, Air Quality Monitor System
Product CodeENE-0003
Freight Extra (Godown Delivery)
In Stock ( 50 Units )

Continuous Ambient Air Quality Monitoring Station EE-CAAQMS-05 (Sox, Nox, Co,Pm 10, Pm 2.5)

 

E&E's Air Quality Monitoring Station (AQMS) Is An Advanced System For Accurate Measurement And Logging Of Meteorological Parameters Including Temperature, Humidity, Wind Direction, Wind Speed, Visibility, UV Light, Light Intensity, And Solar Radiation. It Also Supports Optional Monitoring Of Air Pollutants Such As SO2, NO2, CO, CO2, O3, NH3, H2S, And PM 10 And PM2.5. Customizable To Specific Needs, These Stations Are Ideal For Applications In Agriculture, Hydrology, Ecology, And Meteorology. E&E Solutions Offers Expert Guidance In Selecting The Optimal Combination Of Sensors, Data Loggers, And Accessories To Meet Your Unique Requirements.

 

Features     

  • Compliance With Standards: Meets USEPA Reference Methods For Various Analyzers, Ensuring Accuracy And Reliability In Measurements. Real-Time Monitoring: Continuously Monitors Air Quality With Iot Integration, Providing Real-Time Data On Various Pollutants.
  • Data Transfer And Analysis: Automatically Transfer And Analyzes Data At Customizable Intervals.
  • User-Friendly Interface: Equipped With Large Screens And Multi-Tasking Software, Allowing Easy Viewing And Operation Of Test Variables.
  • Comprehensive Data Logging: Internal Data Logging Capability With Customizable Averaging Intervals.
  • Continuous System Diagnosis: Built-In System Diagnosis With Alarm Features For Immediate Issue Detection And Resolution.
  • Temperature And Pressure Compensation: Ensures Accurate Readings By Compensating For Environmental Variations.
  • Versatile Outputs: Provides Various Output Options Including Ethernet And RS232 For Seamless Data Integration.
  • High Precision And Reliability: Utilizes Advanced Measurement Principles Like UV Fluorescence, Chemiluminescence, And Non-Dispersive Infrared (NDIR) Methods.
  • Minimal Maintenance: Designed For Long-Term Reliability With Minimal Maintenance Requirements, Making It Suitable For Various Environments.

 

Applications

  • Meteorological Monitoring
  • Industrial & Urban Air Quality Mangement
  • Agriculture & Ecology
  • Urban Planning & Development
  • Scientific Studies Research & Development

 

Product Specification
Materials Polycarbonate
Cover Screws Stainless Steel, brass fitting
Ingress Protection IP67
Impact Resistance IK08
Rated Insulated Voltage AC:220V
Ambient Temperature Range  -20°C to 60°C

 

Technology
Module Over air programming (OAP) of nodes at once (via Wi-Fi or 4G telemetry)
Communication RS485 or printer cable for sensor suite to control unit, USB port for downloading data 
File Output Format   Customizable (e.g., CSV, JSON)      

 

Sensor Sox
Principle UV Fluorescence
Standard Range Min: 0-100 ppb F.S. Mix: 0-20 ppm F.S. (Selectable)
Zero Noise <0.4 ppb (RMS)
Span Noise <2.5 ppb
 Lower Detectable Limits  <0.5 ppb
Zero Drift (24 hrs) <1ppb
Span Drift <1% F.S.
Response Time <80s (T90)
Precision <1%
Linearity <1% F.S.
Sample Flow Rate 650 cc/min ±10%
Operating Temperature 20-30°C range (per US EPA Guidelines)

 

NOX
Principle Chemiluminescence
Standard Range Min: 0-100 ppb F.S. Mix: 0-20 ppm F.S. (Selectable)
Zero Noise <0.4 ppb (RMS)
Span Noise <2.5 ppb
 Lower Detectable Limits  <0.4 ppb
Zero Drift (24 hrs) <0.4 ppb
 Span Drift <1% F.S.
Response Time <40s (T90)
Precision <1%
Linearity <1% F.S.
Sample Flow Rate 500 cc/min ±10%
Operating Temperature 20-30°C Range (As per USEPA Guidelines)

 

Carbon Monooxide (CO)
Principle Non-Dispersive infra-Red (NDIR) with Gas filter correlation/ cross Flow Modulation Method
Measurement CO in Ambient Air 
Display Digital
Range Auto ranging 0-100 ppm
Lower Detectable Limit  0.1 ppm
Noise Level 0.05 ppm with time constant ±30 seconds
Zero Drift  < 0.2 ppm/7 days
 Span Drift <1% fullscale in 24 hrs.
Linearity Continous ±1%
Response Time 50 seconds or less
 Analog Output 0 - 1V, 0-10V, 2-20mA/4-20mA
Digital Output Multiple drop RS232 port, USB port/TCP/IP, Ethernet

 

PM10 and PM2.5
Principle Beta Ray Attenuation
Resolution 0.1 µgc
Lower Detectable Limit 0.002 mg/m³
Accuracy <2%
Range (0~1) mg/m3, (0~2)mg/m3, (0~5)mg/m3, (0~10)mg/m3 (selectable) 
Sample Flow Rate 16.L/min
Flow Accuracy ±1% F.S.
 Flow Stability <±2%/24h(operation) 
Calibration Film Reproducibility <±2%
Sample Cycle 60min (Optional)
Source C14 source, active10µCi, exemption sourc
Filter Paper Tape  Glass Fiber
Roll Length >20 meters
Detector PMT

 

Met Station
Ambient Temperature Range: -10 - 60°C
Accuracy : ±0.2°C or better (with radiation Shield)
Response Time : 10 sec
Resolutions : 0.1 °C
Relative Humidity Range: 0 to 100%RH
Accuracy: ±3.0% or better
Resolutions:1%
Response Time: 10 sec
Wind Speed Range: 0 - 60 m/s
Sustainability: Upto 75 m/sec
 Accuracy: ± 0.5 m/sec
Resolution:0.1 m/sec
Threshold: 0.5 m/sec
 Response time:10 sec
Wind Direction Range: 0 - 359 degree
Accuracy: ± 3 degree
Resolution: 1 degree
Threshold: 0.5 m/sec
Response time: 10 sec
Rain Fall Range:0.2 mm to 100 mm /hr
Accuracy: ± 5%
Resolution: 0.2 mm
Response time: 10 sec
Solar Radiation Range: 0 to 1500 W/m²
Accuracy: ± 5.0 %
Resolution: 5W/m2

 

Power Source
Battery Rechargeable lithium-ion
Solar Panel Options Internal Or External
External Solar Panel Mount 45° Holder
Electrical Cable Connector 2/3 Pins IP65 waterproof
Battery Warranty 3 to 5 year for Rechargeable, 1 year for regular batteries
Board Power Voltages 5.5V and 6.5.V
Maximum admitted Current (continuous) 150mA
Maximum admitted Current (peak) 300mA
Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:Continuous Ambient Air Quality Monitoring Station EE-CAAQMS-05 (Sox, Nox, Co,Pm 10, Pm 2.5)
Your Rating
WA button WA button