Analog Heat Detector | FAH-440 | BOSCH
Product Name | Analog Heat Detector | FAH-440 | BOSCH |
---|---|
Weight | 1.000000 |
COUNTRY OF MANUFACTURE | India |
Brand | Bosch |
HSN Code | 8531 |
System Type | CONVENTIONAL |
material | Plastic |
Model | BOSCH-FAS-FAH-440 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Alarm System, Fire Safety, Detectors, Heat Detectors |
Product Code | CPK-0036 |
• Selectable Fixed Temperature threshold
• Rate-of-Rise feature can be switched on or off
• Selectable base locking mechanism prevents malicious removal of the detector
The FAH‐440 Analog Heat Detector is an open-area fire detector that works with the FPA‐1000 Analog
Addressable Fire Panels. Use it with the FAA‐440 family of bases in indoor dry environments with high ambient temperatures where smoke detectors might not be suitable because of steam or fumes; such as kitchens, boiler rooms, or drying rooms.possible to turn on or off operation of the polling indicator. In the event of an alarm condition, the detector LED will always show a steady red light.
Modular Construction
The detector is part of a two‐piece modular design for detector assemblies. A detector attaches to a base in the FAA‐440 Analog Standard Base or Analog Isolator Base family. The base’s security locking tab prevents any unauthorized detector removal from the base.
Selectable Threshold Setting
The detector has an alarm threshold temperature range of +135°F to +194°F (+57°C to +90°C) with 17 possible settings. The rate-of-rise feature can be switched on or off.
Certifications and approvals
Region | Certification | |
USA | UL | UROX Smoke-automatic Fire Detectors (ANSI/UL 268) |
CSFM | see our website |
Installation/configuration notes
Compatible Products
The following products are compatible with the FAH‐440 Analog Heat Detector:
Category | Product ID | Product Description |
Fire Panels | FPA‐1000 Series | Analog Addressable Fire Panels |
Fire Panel Accessories | FPE‐1000‐SLC | Signaling Line Circuit Plug‐in Module |
Detector Bases | FAA‐440‐B4 | 4‐inch Analog Standard Base |
FAA‐440‐B6 | 6‐inch Analog Standard Base | |
FAA-440-B4-ISO | 4‐inch Analog Isolator Base | |
FAA-440-B6-ISO | 6‐inch Analog Isolator Base |
Mounting Considerations
Detectors are typically mounted on the ceiling. However, if detectors are mounted on a wall, they
must be at least 4 in. (10.2 cm), but no more than 12 in. (30.5 cm), below the ceiling. When other
devices containing magnets or producing magnetic fields (for example, loudspeakers) are present in the area, the base must be at least 1 ft (30 cm) from these devices to prevent unwanted activation of the test switch.
For UL Listing requirements, the spacing between heat detectors should be no more than 50 ft (15.24 m).
Wiring Considerations
The control panel communicates to the detectors via the analog addressable loop (SLC), which allows the use of standard non‐twisted, non‐shielded wiring.
Wire Gauge | Maximum length |
18 AWG (ISO 0.75 mm2) | 4000 ft (1200 m) |
16 AWG (ISO 1.5 mm2) | 6225 ft (1900 m) |
14 AWG (ISO 2.5 mm2) | 7200 ft (2200 m) |
12 AWG (ISO 4 mm2) | 9850 ft (3000 m) |
Remote Indicator
If a remote indicator is used in the circuit, it must be no more than 10 ft (3 m) from the base.
Parts included
Quant. | Component |
1 | FAH-440 detector |
1 | Dust cover |
Technical specifications
Electrical
Maximum current consumption detector head at 77°F (25°C) and 39 V
bus voltage
• Alarm: | 5 mA |
• Standby: | 0.17 mA |
• When polled: | 22 mA ± 20% |
Operating voltage (SLC loop): | 24 VDC to 41 VDC |
Maximum allowable line resistance: | 50 Ω |
Environmental
Protection category: | IP 42 |
Relative Humidity: | < 95% (non‐condensing) |
Temperatures
• Installation: | +32°F to +100°F (0°C to +38°C) If the sensitivity temperature is programmed within a range of +175°F to +249°F (+79.4°C to +120.6°C), the maximum installation temperature is +150°F (+66°C). |
• Storage: | -13°F to +176°F (-25°C to +80°C) |
Mechanical
Dimensions
• Detector: | 4.4 in. x 2.0 in. (11.2 cm x 5.1 cm) |
• Detector in 4-inch base: | 5.0 in. x 2.5 in. (12.7 cm x 6.4 cm) |
• Detector in 6-inch base: | 7.0 in. x 2.5 in. (17.8 cm x 6.4 cm) |
Housing Material: | CYCOLOY/ABS |
Sensor
Airflow: | 4000 ft/min (20 m/s) maximum |
Sensitivity: | +135°F to +194°F (+57°C to +90°C), programmable + RoR |
Trademarks
All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
Ordering information
FAH-440 Analog Heat Detector
Use with FAA‐440 family bases and FAP-1000 Analog Addressable Fire Panels to provide general property protection Order number FAH-440
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping & Delivery Policy: |
1. | 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
4. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |