Addressable AVENAR 4000 Smoke Detector Optical | FAP-425-O-R | BOSCH

₹1,827.00 ₹2,155.86
Out of stock
More Information
Product NameAddressable AVENAR 4000 Smoke Detector Optical | FAP-425-O-R | BOSCH
Weight1.000000
COUNTRY OF MANUFACTUREIndia
BrandBosch
HSN Code8531
System TypeADDRESSABLE
ModelFAP-425-O-R
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryAlarm System, Fire Safety, Detectors, Smoke Detector
Product CodeCPK-0060
Freight Extra (Godown Delivery)
Out Of Stock

AVENAR detector 4000

• Highly reliable and accurate thanks to Intelligent Signal Processing (ISP)

• Earliest detection of lightest smoke with dual-optical versions (Dual-Ray   technology)

•Monitors environment for electromagnetic influence for fast root-cause analysis

• Automatic and manual address setting

AVENAR detector 4000 is a new range of automatic fire detectors featuring a superb accuracy and swiftness in detection. The versions with two optical sensors (dual‐optical) are able to detect the lightest smoke.The range includes versions with rotaries, manually and automatically addressable, and versions without rotaries for automatic address setting.

Functions

Sensor technology and signal processing

The individual sensors can be configured in the FSP-5000-RPS programming software.All sensor signals are analysed continuously by the internal evaluation electronics (ISP - Intelligent Signal Processing) and are linked with each other via an inbuilt micro- processor.The link between the sensors means that the combined detectors can also be used where light smoke, steam or dust must be expected during the course of normal operation.Only if the signal combination corresponds to the characteristics of the application site, selected during the programming, the alarm is triggered automatically.This results in less false alarms.In addition, the time of the sensor signals on fire and fault detection is analysed, which leads to high detection reliability for each individual sensor.In the case of the optical and chemical sensor, the response threshold (drift- compensation) is actively adjusted. Manual or time-controlled switch-off of individual sensors is possible for adjustment to extreme interference factors.

Optical sensor (smoke sensor)
The optical sensor uses the scattered-light method.An LED transmits light to the measuring chamber, where it is absorbed by the labyrinth structure. In the event of a fire, smoke enters the measuring chamber and the smoke particles scatter the light from the LED.The amount of light hitting the photo diode is converted into a proportional electrical signal.The dual-optical versions use two optical sensors with different wavelengths. The Dual-Ray technology works with an infrared and a blue LED so that lightest smoke
is detected fast and reliably (TF1 and TF9 detection).


Thermal sensor (temperature sensor)
A thermistor in a resistance network is used as a thermal sensor from which an analog-digital converter measures the temperature-dependent voltage at
regular intervals.Depending on the specified detector class, the temperature sensor triggers the alarm status when the maximum temperature of 54 °C or 69 °C is exceeded (thermal maximum), or if the temperature rises by a
defined amount within a specified time (thermal differential).

Chemical sensor (CO gas sensor)
The main function of the gas sensor is to detect carbon monoxide (CO) generated as a result of a fire,but it will also detect hydrogen (H) and nitrous
monoxide (NO). The sensor signal value is proportional to the concentration of gas. The gas sensor delivers additional information to effectively suppress
deceptive values.Since the service life of the gas sensor is limited, the C
sensor shuts down automatically after a maximum of 6 years of operation. The detector will then still operate as a multi-sensor detector with dual-optical and thermal sensor. It is recommended to exchange the detector immediately in order to keep the higher detection reliability of the version with C sensor.

Improved LSN features
AVENAR detector 4000 offers all the features of the improved LSN technology:
•  Flexible network structures, including T‐tapping without additional         elements (no T-tapping feasible for versions without rotaries)
• Up to 254 LSN improved elements per loop or stub line
• Automatic or manual detector addressing, with or without auto-detection
• Power supply for connected elements via LSN bus
• Unshielded fire detection cable can be used
• Cable length up to 3000 m (with LSN 1500 A)
• Backwards compatibility to existing LSN systems and central units
• Monitoring of environmental electromagnetic impact for fast root-cause analysis (EMC values are displayed on the panel)

In addition, the range offers all the established benefits of LSN technology. The panel programming software can be used to change the detection characteristics of the respective room utilization. Each configured detector can provide the following data:
• Serial number
• Contamination level of the optical section
• Operating hours
• Current analog values
  – Optical system values: current measured value of the scattered light sensor; the measuring range is linear and shows different degrees of pollution, from slight to heavy.
  – Contamination: the contamination value shows how much the current contamination value has increased relative to the original condition.
 – CO value: display of the currently measured value.

The sensor is self-monitoring. The following errors are
indicated on the fire panel:
• Fault indication in the event of the failure of the detector electronic

• Continuous display of contamination level during service

• Fault indication if heavy contamination is detected
(instead of triggering a false alarm)
In the event of wire interruption or short-circuit,integrated isolators maintain the functional security of the LSN loop.
In the event of an alarm, individual detector identification is transmitted to the fire panel.

Further characteristics
• A red flashing LED visible 360° indicates the alarm.
• Connection to a remote indicator is possible.
• The strain relief for cables in false ceilings prevents the cables from being      unplugged accidentally from the terminals after installation. The terminals      for cable cross-sections up to 2.5 mm2 are very easily accessible.
• The detectors have a dust-repellent labyrinth and cap construction. The   chamber maid plug (an opening with closing plug) on the bottom is used to   clean the optical chamber with compressed air (not required for the heat     detector).
• The detector bases no longer have to be directed due to the centralized         position of the individual display. They also have a mechanical removal lock (can be activated and deactivated).

Certifications and approvals

Region   Regulatory compliance/quality marks
Europe CPR 0786-CPR-21402 FAH-425-T-R
  CPR 0786-CPR-21403 FAP-425-DO-R
  CPR 0786-CPR-21405 FAP-425-DOTC-R
  CPR 0786-CPR-21404 FAP-425-DOT-R
  CPR 0786-CPR-21398 FAP-425-O
  CPR 0786-CPR-21399 FAP-425-O-R
  CPR 0786-CPR-21400 FAP-425-OT
  CPR 0786-CPR-21401 FAP-425-OT-R
Germany VdS G214100 FAP-425-O
  VdS G214099 FAP-425-O-R
  VdS G214098 FAP-425-OT
  VdS G214097 FAP-425-OT-R
  VdS G214101 FAH-425-T-R
  VdS G214104 FAP-425-DO-R
  VdS G214103 FAP-425-DOT-R
  VdS G214102 FAP-425-DOTC-R
Europe CE FAP/FAH/FAD-425
  CE FAP-425

Installation/configuration notes

• Connectable to Bosch fire panels with the improved LSN system       parameters.

• You can use the DO detectors only with the Panel Controller MPC version B    and higher. The Panel Controller MPC version A cannot be connected.
• In LSN classic mode connectable to the LSN fire panels BZ 500 LSN, UEZ     2000 LSN, UGM 2020 and to other panels or their receiver modules with     identical connection conditions, although with the previous LSN system       parameters
• During planning works, it is essential to adhere to national standards and     guidelines.
• The detector can be painted (cap and base) and thereby adapted to the     surrounding colour scheme.Note the information in the Painting Instructions.
• Detectors of the 420 series can be replaced by all versions of the AVENAR      detector 4000 without re-configuring the panel.

Installation/configuration notes in accordance with
VdS/VDE
• The FAP‐425-DOTC-R, FAP‐425-DOT-R, FAP‐425-OT-R,and FAP‐425-OT   versions are planned in accordance with the guidelines for optical detectors if operated as optical detectors or as combined optical/thermal detectors (see DIN VDE 0833 Part 2 and VDS 2095)
• If occasional deactivation of the optical unit (scattered light sensor) is   required, planning must be based on the guidelines for heat detectors (see
 DIN VDE 0833 Part 2 and VDS 2095)
• When planning fire barriers according to DIBt, note that the heat detector (FAH-425-T-R) must be configured in accordance with class A1R.

Technical specifications

Electrical
Operating voltage 15 V DC to 33 V DC
Current consumption < 0.55 mA
Alarm output

Per data word by two-wire signal line

Indicator output Open collector connects 0 V over 1.5 kΩ through, max.15 mA
Mechanics
Dimensions  
• Without base Ø 99.5 x 52 mm
• With base Ø 120 x 63.5 mm
Housing  
• Material Plastic, ABS (Novodur)
• Color

White, similar to RAL 9010,matt finish

Weight  
• FAP-425-DOTC-R Approx. 85 g / Approx. 130 g
• FAP-425-DO-R,
  FAP-425-DOT-R
Approx. 80 g / Approx. 120 g
• FAP-425-O-R,
  FAP-425-OT-R,
  FAH-425-T-R
Approx. 80 g / Approx. 120 g
• FAP-425-O, FAP-425-OT Approx. 75 g / Approx. 115
Environmental conditions
Permissible operating temperature
• FAP-425-DOTC-R -10°C to +50°C
• FAP-425-DOT-R,
  FAP-425-OT-R,
  FAH-425-T-R,
  FAP-425-OT
-20°C to +50°C
• FAP-425-DO-R,
FAP-425-O-R,
FAP-425-O
-20°C to +65°C

Permissible storage

temperature

 

 

• FAP-425-DOTC-R -20°C to +50 °C
• All versions (except for
  FAP-425-DOTC-R)
-25°C to +80°C
Permissible relative humidity 95% (non-condensing)
Permissible air speed 20 m/s.
Degree of protection (IEC 60529)

IP41 ,

IP43 with detector base and
FAA-420-SEAL or MSC 420

Further characteristics
Response sensitivity
• Optical part In accordance with EN 54-7
(programmable)
• Thermal maximum part > 54°C / > 69°C
• Thermal differential part:
• FAH-425-T-R
A2S / A2R / A1 / A1R / BS /
BR, in line with EN 54‐5
(programmable)
• Thermal differential part:
• FAP-425-DOTC-R,
FAP-425-DOT-R,
FAP-425-OT-R,
FAP-425-OT
A2S / A2R / BS / BR, in line
with EN 54-5 (programmable)
• Gas sensor In ppm range
Individual display LED red and green
Color code
• FAP-425-O-R,
FAP-425-O
No marking
• FAP-425-OT-R,
FAP-425-OT
Black loop
• FAH-425-T-R Red loop
• FAP-425-DO-R 2 gray concentric loops
• FAP-425-DOT-R 2 black concentric loops
• FAP-425-DOTC-R 2 yellow concentric loops
Limits  
Heed local guidelines. They overrule the following
limits.
Monitoring area
• All versions (except for
FAH-425-T-R)
Max. 120 m2
• FAH-425-T-R Max. 40 m2
Maximum installation height
• All versions (except for
FAH-425-T-R)
Max. 16 m
• FAH-425-T-R Max. 7.5 m
Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:Addressable AVENAR 4000 Smoke Detector Optical | FAP-425-O-R | BOSCH
Your Rating
WA button WA button