Description

Overload Relay 11...16 A Thermal For Motor Protection Size S2, Class 10 Contactor Mounting Main Circuit: Screw Auxiliary Circuit: Screw Manual-Automatic-Reset

 

Product Brand Name  Sirius
Product Designation  Thermal Overload Relay
Product Type Designation  3RU2
Model No 3RU2136-4AB0

 

General Technical Data
Size Of Overload Relay S2
Size Of Contactor Can Be Combined Company-Specific  S2
Power Loss [W] For Rated Value Of The Current At AC In Hot Operating State 10.5 W
Per Pole  3.5 W
Insulation Voltage With Degree Of Pollution 3 At AC Rated Value  690 V
Surge Voltage Resistance Rated Value  6 kV
Maximum Permissible Voltage For Protective Separation
In Networks With Ungrounded Star Point Between Auxiliary And Auxiliary Circuit 415 V
In Networks With Grounded Star Point Between Auxiliary And Auxiliary Circuit 415 V
In Networks With Ungrounded Star Point Between Main And Auxiliary Circuit 690 V
In Networks With Grounded Star Point Between Main And Auxiliary Circuit 690 V
Shock Resistance According To IEC 60068-2-27  8g / 11 Ms
Recovery Time After Overload Trip
With Automatic Reset Typical  10 min
With Remote-Reset  10 min
With Manual Reset  10 min
Reference Code According To IEC 81346-2  F
Substance Prohibitance (Date) 10/15/2014
SVHC Substance Name  Lead - 7439-92-1
Weight  0.322 kg
Ambient Conditions
Installation Altitude At Height Above Sea Level Maximum  2 000 m
Ambient Temperature
During Operation  -40 ... +70 °C
During Storage  -55 ... +80 °C
During Transport  -55 ... +80 °C
Temperature Compensation  -40 ... +60 °C
Relative Humidity During Operation  10 ... 95 %
Environmental Footprint
Global Warming Potential [CO2 Eq] Total  108 kg
Global Warming Potential [CO2 Eq] During Manufacturing  1.8 kg
Global Warming Potential [CO2 Eq] During Sales  0.083 kg
Global Warming Potential [CO2 Eq] During Operation  107 kg
Global Warming Potential [CO2 Eq] After End Of Life  -0.063 kg
Main Circuit
Number Of Poles For Main Current Circuit  3
Adjustable Current Response Value Current Of The Currentdependent Overload Release 11 ... 16 A
Operating Voltage
Rated Value  690 V
At AC-3e Rated Value Maximum  690 V
Operating Frequency Rated Value 50 ... 60 Hz
Operational Current Rated Value  16 A
Operational Current At AC-3e At 400 V Rated Value  16 A
Operating Power
at AC-3
At 400 V Rated Value  7.5 kW
At 500 V Rated Value  7.5 kW
At 690 V Rated Value  11 kW
at AC-3e
At 400 V Rated Value  7.5 kW
At 500 V Rated Value  7.5 kW
At 690 V Rated Value 11 kW
Auxiliary Circuit
Design Of The Auxiliary Switch Integrated
Number Of NC Contacts For Auxiliary Contacts 1
Note  For Contactor Disconnection
Number Of NO Contacts For Auxiliary Contacts  1
Note  For Message "Tripped"
Number Of CO Contacts For Auxiliary Contacts  0
Operational Current Of Auxiliary Contacts At AC-15
at 24 V 3 A
at 110 V  3 A
at 120 V  3 A
at 125 V  3 A
at 230 V  2 A
at 400 V  1 A
at 690 V  0.75 A
Operational Current Of Auxiliary Contacts At DC-13
at 24 V  2 A
at 60 V  0.3 A
at 110 V  0.22 A
at 125 V  0.22 A
at 220 V  0.11 A
Design Of The Miniature Circuit Breaker For Short-Circuit Protection Of The Auxiliary Switch Required 6A (SCC Less Than Equal To 0.5 kA; U Less Than Equal To 260V)
Contact Rating Of Auxiliary Contacts According To UL  B600 / R300
Protective And Monitoring Functions
Trip Class  Class 10
Design Of The Overload Release  Thermal
UL/CSA Ratings
Full-Load Current (FLA) For 3-Phase AC Motor
at 480 V Rated Value  16 A
at 600 V Rated Value  16 A
Short-Circuit Protection
Design Of The Fuse Link
For Short-Circuit Protection Of The Auxiliary Switch Required  Fuse gG: 6 A, Quick: 10 A
Installation/ Mounting/ Dimensions
Fastening Method  Contactor Mounting
Height  90 mm
Width  55 mm
Depth  105 mm
Connections/ Terminals
Product Component Removable Terminal For Auxiliary And  No
Control Circuit
Type Of Electrical Connection
For Main Current Circuit  Screw-Type Terminals
For Auxiliary And Control Circuit  Screw-Type Terminals
Arrangement Of Electrical Connectors For Main Current Circuit Top And Bottom
Type Of Connectable Conductor Cross-Sections
For Main Contacts
Solid Or Stranded  2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
Finely Stranded With Core End Processing  2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
For AWG Cables For Main Contacts 2x (18 ... 2), 1x (18 ... 1)
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
Solid Or Stranded  2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Finely Stranded With Core End Processing  2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
For AWG Cables For Auxiliary Contacts  2x (20 ... 16), 2x (18 ... 14)
Tightening Torque
For Main Contacts With Screw-Type Terminals  3 ... 4.5 N·m
For Auxiliary Contacts With Screw-Type Terminals  0.8 ... 1.2 N·m
Design Of Screwdriver Shaft  Diameter 5 ... 6 mm
Size Of The Screwdriver Tip  Pozidriv PZ 2
Design Of The Thread Of The Connection Screw
For Main Contacts  M6
Of The Auxiliary And Control Contacts  M3
IEC 61508
T1 value
For Proof Test Interval Or Service Life According To IEC 61508 20 a
Protection Class IP On The Front According To IEC 60529  IP20
Touch Protection On The Front According To IEC 60529  Finger-Safe, For Vertical Contact From The Front
Display
Display Version For Switching Status  Slide Switch
Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:3RU2136-4AB00-8K Thermal Overload Relay 11...16 Siemens Size S2, Class 10 Contactor Mounting
Your Rating
WA button WA button