3RU2116-1CB00-8K Thermal Overload Relay 1.8...2.5 Siemens Size S00, Class 10 Contactor Mounting

₹1,287.00 ₹1,518.66
In stock
More Information
Product Name3RU2116-1CB00-8K Thermal Overload Relay 1.8...2.5 Siemens Size S00, Class 10 Contactor Mounting
Weight0.160000
BrandSiemens
Test CertificateNo
COUNTRY OF MANUFACTUREIndia
SizesS00
Model3RU2116-1CB00-8K
HSN Code85364900
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryElectrical, Relays & Contactor, Thermal Overload Relay
Product CodeTNB-0585
Freight Extra (Godown Delivery)
In Stock ( 200 Units )

3RU2116-1CB00-8K Thermal Overload Relay 1.8...2.5 Siemens Size S00, Class 10 Contactor Mounting

 

Description

Overload Relay 1.8...2.5 A Thermal For Motor Protection Size S00, Class 10 Contactor Mounting Main Circuit: Screw Auxiliary Circuit: Screw Manual-Automatic-Reset

 

Product Brand Name Sirius
Product Designation  Thermal Overload Relay
Product Type Designation  3Ru2
Model No 3RU2116-1CB0

 

General Technical Data
Size Of Overload Relay  S00
Size Of Contactor Can Be Combined Company-Specific  S00
Power Loss [W] For Rated Value Of The Current At AC In Hot Operating State 5.7 W
Per Pole  1.9 W
Insulation Voltage With Degree Of Pollution 3 At AC Rated Value  690 V
Surge Voltage Resistance Rated Value 6 kV
Maximum Permissible Voltage For Protective Separation
In Networks With Ungrounded Star Point Between Auxiliary And Auxiliary Circuit 440 V
In Networks With Grounded Star Point Between Auxiliary And Auxiliary Circuit 440 V
In Networks With Ungrounded Star Point Between Main And Auxiliary Circuit 440 V
In Networks With Grounded Star Point Between Main And Auxiliary Circuit 440 V
Shock Resistance According To IEC 60068-2-27 8g / 11 Ms
Reference Code According To IEC 81346-2  F
Substance Prohibitance (Date)  10/01/2009
Svhc Substance Name  Lead - 7439-92-1
Weight 0.16 kg
Ambient Conditions
Installation Altitude At Height Above Sea Level Maximum 2 000 m
Ambient Temperature
During Operation -40 ... +70 °C
During Storage -55 ... +80 °C
During Transport -55 ... +80 °C
Temperature Compensation -40 ... +60 °C
Relative Humidity During Operation  10 ... 95 %
Environmental Footprint
Global Warming Potential [CO2 Eq] Total  39.9 kg
Global Warming Potential [CO2 Eq] During Manufacturing  0.921 kg
Global Warming Potential [CO2 Eq] During Sales 0.039 kg
Global Warming Potential [CO2 Eq] During Operation  39 kg
Global Warming Potential [CO2 Eq] After End Of Life  -0.015 kg
Main Circuit
Number Of Poles For Main Current Circuit  3
Adjustable Current Response Value Current Of The Current 

1.8 ... 2.5 A

Dependent Overload Release
Operating Voltage
Rated Value 690 V
At AC-3e Rated Value Maximum  690 V
Operating Frequency Rated Value  50 ... 60 Hz
Operational Current Rated Value  2.5 A
Operational Current At AC-3e At 400 V Rated Value  2.5 A
Operating Power
At AC-3
At 400 V Rated Value  0.75 kW
At 500 V Rated Value  1.1 kW
At 690 V Rated Value  1.5 kW
At AC-3e
At 400 V Rated Value  0.75 kW
At 500 V Rated Value  1.1 kW
At 690 V Rated Value  1.5 kW
Auxiliary Circuit
Design Of The Auxiliary Switch  Integrated
Number Of NC Contacts For Auxiliary Contacts  1
Note  For Contactor Disconnection
Number Of No Contacts For Auxiliary Contacts  1
Note  For Message "Tripped"
Number Of Co Contacts For Auxiliary Contacts  0
Operational Current Of Auxiliary Contacts At AC-15
at 24 V  3 A
at 110 V  3 A
at 120 V  3 A
at 125 V  3 A
at 230 V  2 A
at 400 V 1 A
at 690 V 0.75 A
Operational Current Of Auxiliary Contacts At DC-13
at 24 V  2 A
at 60 V  0.3 A
at 110 V 0.22 A
at 125 V  0.22 A
at 220 V  0.11 A
Contact Rating Of Auxiliary Contacts According To UL B600 / R300
Protective And Monitoring Functions
Trip Class  Class 10
Design Of The Overload Release Thermal
Ul/Csa Ratings
Full-Load Current (Fla) For 3-Phase Ac Motor
at 480 V Rated Value  2.5 A
at 600 V Rated Value  2.5 A
Short-Circuit Protection
Design Of The Fuse Link
For Short-Circuit Protection Of The Auxiliary Switch Required  Fuse gG: 6 A, Quick: 10 A
Installation/ Mounting/ Dimensions
Fastening Method  Contactor Mounting
Height 76 mm
Width 45 mm
Depth 70 mm
Connections/ Terminals
Product Component Removable Terminal For Auxiliary And Control Circuit No
Type Of Electrical Connection
For Main Current Circuit  Screw-Type Terminals
For Auxiliary And Control Circuit Screw-Type Terminals
Arrangement Of Electrical Connectors For Main Current Circuit Top And Bottom
Type Of Connectable Conductor Cross-Sections
For Main Contacts
Solid Or Stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm²
Finely Stranded With Core End Processing  2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
For AWG Cables For Main Contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12
Type Of Connectable Conductor Cross-Sections
For Auxiliary Contacts
Solid Or Stranded 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Finely Stranded With Core End Processing  2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
For AWG Cables For Auxiliary Contacts 2x (20 ... 16), 2x (18 ... 14)
Tightening Torque
For Main Contacts With Screw-Type Terminals  0.8 ... 1.2 N·m
For Auxiliary Contacts With Screw-Type Terminals 0.8 ... 1.2 N·m
Design Of Screwdriver Shaft  Diameter 5 ... 6 mm
Size Of The Screwdriver Tip  Pozidriv PZ 2
Design Of The Thread Of The Connection Screw
For Main Contacts  M3
Of The Auxiliary And Control Contacts M3
Safety Related Data
Failure Rate [FIT] With Low Demand Rate According To Sn 31920 50 FIT
Mttf With High Demand Rate 2 280 a
IEC 61508
T1 Value
For Roof Test Interval Or Service Life According To IEC 61508 20 a
Electrical Safety
Protection Class IP On The Front According To IEC 60529  IP20
Touch Protection On The Front According To IEC 60529  Finger-Safe, For Vertical Contact From The Front
Display
Display Version For Switching Status  Slide Switch

 

Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:3RU2116-1CB00-8K Thermal Overload Relay 1.8...2.5 Siemens Size S00, Class 10 Contactor Mounting
Your Rating
WA button WA button