• FPC-500 Conventional Fire Panel
• High-value modern optics – suitable for public access areas
• Plain text LCD
• Available for 2, 4 or 8 detector zones for up to 64,128 or 256 detectors
• Optional use of EOL module (EN 54-13 requirement)
• Strong 3 A power supply
The FPC‐500‐x Conventional Fire Panel is the ideal solution for small and medium-sized objects. Thanks to the proven conventional line technology a cost-saving fire alarm system can be set up.
Three types are available:
• FPC‐500‐2: 2 zones for up to 64 detectors
• FPC‐500‐4: 4 zones for up to 128 detectors
• FPC‐500‐8: 8 zones for up to 256 detectors
With the integrated LCD display, the panel can be programmed and operated.
The optional extensions such as relay modules, open collector modules and key switches allow further tailoring to user needs.
Z1...Z8 Up to 8 zones
IN1, IN2 Up to 2 inputs (FPC‐500‐2 and FPC‐500 4 one input) Two NAC outputs (500 mA each)
ALARM RLY, Alarm and fault relay
FAULT RLY
AUX AUX power supply (500 mA)
Emergency power supply, up to 2 x 7.2 Ah
1 LEDs
2 LCD display with zone numbers
3 Zone keys and zone status LEDs
4 Operating panel
Functions
The fire panels of FPC-500 series have the following features available:
• Alarm verification
• Dual-detector dependency
• Dual-zone dependency
• Intermediate alarm storage
• Programmable delays
• Switching between day and night mode (AV)
• Event and test history
• Alarm counter
Operating levels
The fire panels have three different operating levels.No access code is required for level 1. Access to level 2 and 3 requires four-digit codes (level 2 also accessible with optional key switch).The access codes for level 2 and 3 can be changed.Different test functions are available. On level 1 LED,buzzer and LCD tests can be run. On level 2 and 3 additional tests for zones, outputs and NACs can be run.
Programming
You can program the panel easily via the keypad and LCD display. The zones can be configured independently allowing for a perfect tailoring to individual customer needs. The default programming helps getting acquainted quickly with the system and must be modified slightly to fit many applications.
Certifications and approvals
The provided options according to EN 54‐2:1997/A1:2006 include:
• Alarm counter
• Test condition
• Output to fire alarm devices
• Delays to outputs
• Dependencies on more than one alarm signal
– Type A dependency
– Type B dependency
Region | Certification | |
Germany | VdS | VdS-G211100 FPC-500 |
Europe | CE | FPC-500 |
CPD | 0786-CPD-21105 FPC-500 | |
Belgium | BOSEC | FPC-500 EN54-13 |
Hungary | TMT | TMT-15/2012 FPC-500 |
Croatia | ELTEH | 145-SF/12 FPC 500 |
Installation/configuration notes
• The fire panel must be mounted indoors in a dry,maintained place, note environmental conditions (seeTechnical Data).
• Mount the fire panel to the wall with the LCD at eye level.
• For optimum battery life, the fire panel should only be operated at permissible operating temperatures (0°C to +40°C).
• Country-specific standards and guidelines must be observed when planning.
• Note the requirements of your local authorities and institutions (police, fire service).
• For an operation of the fire detection system according to EN 54‐13, it is required to terminate every zone with an EOL module.
Maintenance
Have maintenance and inspection work carried out regularly by trained, qualified personnel. Bosch Sicherheitssysteme GmbH recommends a functional and visual inspection at least once a year.
Specifications according to EN 54-4 chapter 7.1
a) It is a power supply equipment, used in the fire alarm system FPC‐500. It supplies the fire alarm system and the connected peripherals, and charges
the two connectable batteries.b) Technical specifications
1) Recommended load | 61 W |
2) Input voltage | 230 VAC +10%/-15%, 50-60 Hz |
Operating voltage | 26 VDC – 29 VDC |
3) Communication parameter | none |
4) Fuse ratings | 3.15A / 250 V |
5) Batteries |
2 x 7.0 – 7.2 Ah (max.) Lead-Acid Battery |
6) Current consumption, max | 2.3 A |
7) Battery, max. internal resistance |
800 mOhm |
Imin | 70 mA |
Imax, a | 0.7 A |
Imax, b | 2.3 A |
8) Line parameter | |
Battery | Cable comes standard |
PCB power supply | factory-made wiring |
230 V power supply |
1.5 mm2 standard cable (max.) |
c) The power supply equipment is a pre-assembled part of the FPC‐500 Conventional Fire Panel.No additional installation information is required.
1) For environmental conditions see technical specifications beneath.
2) The power supply equipment is a pre-assembled part of the FPC‐500 Conventional Fire Panel.Noadditional mounting instructions are required.
3) Refer to installation guide FPC‐500 for connecting instructions.
d) The power supply equipment is a pre-assembled part of the FPC‐500 Conventional Fire Panel.No additional commissioning instructions are required.
e) The power supply equipment is a pre-assembled part of the FPC‐500 Conventional Fire Panel.No additional operating instructions are required.f) Have maintenance and inspection work carried out regularly by trained, qualified personnel. Bosch Sicherheitssysteme GmbH recommends a functional and visual inspection at least once a year.Change the batteries regularly. Country-specific standards and guidelines must be considered.
Parts included
Qty. Components
1 Fire panel FPC-500-2/FPC-500-4/FPC-500-8
1 Labeling strips for zones
1 Labeling strips for LEDs
1 Quick Installation Guide
1 Quick Operation Guide
1 CD with Installation and User Guide, battery calculator and software flashing tool
1 EOL resistors for zones and inputs
1 Battery cable set
1 Cable ties for strain relief on power supply feeder
2 Rubber pads to fix batteries
Technical specifications
FPC‐500‐2 | |||||||||
Detector zones | 2 | ||||||||
Max. number of detectors in accordance with EN 54‐2 |
64 | ||||||||
Max. extension modules |
0 | ||||||||
AUX output | 1 | ||||||||
NAC output | 2 | ||||||||
Relays | 2 | ||||||||
Alarm counter | 999 alarms | ||||||||
Event history | 1000 events | ||||||||
Test history | 1000 test events | ||||||||
Electrical | |||||||||
Input voltage | 230 VAC +10%/-15%, 50-60 Hz | ||||||||
Max. current consumption AC |
275 mA | ||||||||
Power consumption | 80 W | ||||||||
Operating voltage | 21.4 VDC to 29 VDC | ||||||||
Imin | 70 mA | ||||||||
Imax, a | 0.7 A | ||||||||
Imax, b | 2.3 A | ||||||||
Zones |
|
||||||||
AUX |
|
||||||||
NAC |
|
||||||||
Relay outputs |
|
||||||||
OC outputs | No inductive load. | ||||||||
• contact rating | 20 mA @ 24 VDC | ||||||||
• max. cable resistance |
22.5 Ω | ||||||||
recommended cable type |
Unshielded cable, 0.8 mm cable diameter to 1.5 mm2 cable cross section |
||||||||
Batteries | 2 x 7.2 Ah (max.) | ||||||||
• max. internal resistance |
800 mΩ | ||||||||
• current consumption |
2.3 A | ||||||||
• fuse | 5 A @ 60 V | ||||||||
Discharge voltage threshold |
21.4 V | ||||||||
Communication parameters | |||||||||
Normal | |||||||||
• A- | 10 – 15 V | ||||||||
• B+ | 0 – 0,5 V | ||||||||
Alarm | |||||||||
• A- | 0 – 1 V | ||||||||
• B+ | 0 – 1 V | ||||||||
Inputs | |||||||||
• Alarm resistor | 820 Ω ±5% | ||||||||
• End of line resistor | 3.9 kΩ ±1% | ||||||||
Zone (with resistors) | |||||||||
• Alarm resistor | 820 Ω ±5% 910 Ω ±5% No dual-detector dependency: 680 Ω ±5% |
||||||||
• End of line resistor | 3.9 kΩ ±1% | ||||||||
Zone (with EOL-Module) | |||||||||
• Alarm resistor | 820 Ω ±5% 910 Ω ±5% No dual-detector dependency: 680 Ω ±5% |
||||||||
Mechanics | |||||||||
Dimensions ( H x W x D) |
351 x 351 x 90 mm | ||||||||
Weight | 2200 g, without batteries | ||||||||
Housing material |
|
||||||||
Housing color |
|
||||||||
Environmental conditions | |||||||||
Protection class as per IEC 60529 |
IP 30 | ||||||||
Protection class as per EN 60950 |
II | ||||||||
EMC emmission | EN 61000-6-3 | ||||||||
EMC immunity | EN 50130-4 | ||||||||
Vibrations | EN 60068-2-6 | ||||||||
Permissible operating temperature |
0°C to +40°C | ||||||||
Permissible storage temperature |
-10°C to +55°C | ||||||||
Permitted relative humidity |
95% non-condensing |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping & Delivery Policy: |
1. | 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
4. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |