Electromagnetic Flow Meter Accumax 6"

₹44,720.00 ₹52,769.60
In stock
More Information
Product NameElectromagnetic Flow Meter Accumax 6"
Weight1.000000
BrandACCUMAX
Test CertificateNo
COUNTRY OF MANUFACTUREIndia
Power supply85-300 VAC / 24VDC
ACCURACY0.5 % of F.S.
HSN Code90282000
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryHydraulics, Hydraulic Accessories, Measuring Equipments, Water Flow Meter, Electromagnetic Flow Meter
Product CodeVES-0004
Freight Extra (Godown Delivery)
In Stock ( 100 Units )

Electromagnetic Flow Meter Accumax 6"

 

Electromagnetic Flow Meter_150NB (6) Flow Range: 15.9-318 m3/H


* Make: ACCUMAX
* Liner: PTFE
* Type: Integral Display
* Display: Standard 16*2 LCD
* Output: 4-20mA, RS485, Pulse
* Power Supply: 85-300 VAC /
24VDC
* Connection: Flange End - MS,
ANSI #150
* Coil Housing: MS
* Flow Tube: SS304
* Electrode MOC: SS316L
* Flow Direction: Forward &
Reverse
* Accuracy: 0.5 % of F.S.
* Protection: IP66
* Pressure: Max 16 kg/cm2
* Temp: Max 100 DegC
* Liquid Conductivity should be =>
10 Microsiemens/cm

The Accumax’s Electromagnetic Flow Meter is a highly advanced and dependable instrument,
specifically designed to accurately measure flow rates in conductive liquids, acids, alkalies, water,
pulps, and slurries. For various industrial applications, the flow meter provides a maintenance-free solution with an unparalleled blend of performance, flexibility, and cost-effectiveness.Its non-intrusive design makes it perfect for applications where contamination is a problembecause it doesn’t require any contact with the fluid. It also has a high degree of accuracy,typically within 0.5% of full scale.

Working Principle: In Electromagnetic Flow Meter,
the magnetic field is generated by a set of coils. As the conductive liquid passes through the electromagnetic field, an electric voltage is induced in the liquid which is directly proportional to its velocity. The induced voltage is perpendicular to both the liquid flow direction and the electromagnetic field direction

Key Features
• High precision: Often within 0.5% of the reading.
• Broad Measuring Range: With a measuring range
of 0.2 m3
/h to 1300 m3
/h, this device is suitable for
a wide range of applications.
• No moving parts: Non-invasive measurement
techniques guarantee excellent dependability.
• Universal Power Supply: 85 V AC-270 V AC, 50 Hz-60 Hz/ 24 V DC.
• Bidirectional measurements: Measurements
that can be made in both directions—forward and
backward.
• Designed for tough settings and highly corrosive
or abrasive liquids, this material is resistant to
wear and tear.
• Unaffected by fluid characteristics: The flow
meter’s measurement accuracy is unaffected by
variations in the temperature, pressure, density, or viscosity of the fluid.
• Flameproof (IS/IEC 60079-1:2007)/
Weatherproof/ Can function in Potentially
Explosive Atmosphere (IS/IEC 60079-0: 2004)
• Empty pipe alert

Application Areas
• Water & Wastewater Treatment
• Food & Beverage Industry
• Chemical & Pharmaceutical Industries
• Paper & Pulp Industry
• Mining & Metallurgical Industries
• Oil and gas
• Power generation (Cooling stations)

• Effluent Treatment Plants
• Textile Industry
• Ceramic Industry
• Marine Industry
• Nuclear Industry (Cooling stations)
• Sustainable Energies Industry

 

TECHNICAL SPECIFICATIONS
Measurement Principle Electromagnetic
Line Size Options 15 NB To 350 NB (½ inches to 14 inches)
Types Available Integral/ Remote (Up to 10 m Cable Length)
Flow Measuring Range  0.2 m3 /h to 1300 m3 /h
Measured Variables Volume flow, mass flow
Accuracy (or Max. Measurement error)  0.5% of F. S. (or ±0.5%)
Repeatability  ±0.1%
Protection Class  Flow Sensor Unit: IP66/ IP67/ IP68
Transmitter/ Display Unit: IP65/ IP66
Liner PTFE (Teflon)
Process Connection  Flange End
Flange Material  MS / CS / SS304 / SS316
Flange Class #150
Coil Housing Material  MS / CS / SS304 / SS316
Flow Tube SS304/ SS316
Electrode Material  SS316L/ Hastelloy C22
Media Conductive Liquid
Flow Direction Forward & Reverse (Reverse flow indicated with (-) sign before
flow rate)
Electrical Conductivity of Liquid  >5 µS/cm
Operating Temperature Range (Medium
Temperature Range)
2-10 (0) °C to +100 °C C23 -10 (0) °C to +200 °C (Remote display) PTFE: up to 230 °C
Ambient Temperature Range  -25 °C to +60 °C
Relative Humidity 0-95%
Display Unit
Display  Standard 16*2 LCD
Display Resolution/ Smallest Division Flow-rate: 0.01 L/min or 0.01 m3
/h
Totalizer: 9 digits Totalizer

 

TECHNICAL SPECIFICATIONS
Power Supply  85 V AC-270 V AC, 50 Hz-60 Hz/ 24 V DC

Optional power supply

1. Solar powered with 30 hours uninterrupted operation
through 24 V rechargeable battery pack, in absence of
sunlight
2. 3.7 V Rechargeable Li-ion Battery operated
Output 4-20 mA/ RS485/ Pulse
(All three outputs available for non-telemetry flow-meter)
(In Inbuilt Telemetry- None available externally as Gateway by default uses RS-485
In External Telemetry- Gateway connects with RS-485 and 4-20
mA/ Pulse outputs remain available)
Power Consumption <10 VA
Isolation 1.4 kV between Input, Output & Power Supply
Alarm Output Low & High Flow Alarm (Open Drain)
Transmitter Housing Material  Die-cast Aluminum
   
Configuration functions/parameters
Configuration Data 3 Tactile Membrane Keys for Data Configuration
Flow Totalizer Reset Totalizer Reset Facility by Password Protection
Units of Measurement L, m3 , kg, kL (User Configurable)
Low Flow Cut-Off User Configurable- 0 to 10%
Damping Time User Configurable
Security Password Protection for Configuration of Data
Special Function (As Optional Accessories)
Batching Facility Available
Data Logging Available
Telemetry Available
Certifications and Warranty
Meteorological Approvals and Certificates Calibration performed on accredited calibration facilities (acc.
To ISO/IEC 17025) (NABL Calibration) (provided at extra cost)
Other Approvals C E, ISO 4064:2014
Warranty  1 Year

 

Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping & Delivery Policy:
1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
Write Your Own Review
You're reviewing:Electromagnetic Flow Meter Accumax 6"
Your Rating
WA button WA button