12V 15Amps Power Supply
Product Name | 12V 15Amps Power Supply |
---|---|
Weight | 1.000000 |
COUNTRY OF MANUFACTURE | India |
Brand | Sanstar |
HSN Code | 85044090 |
System Type | CONVENTIONAL |
Model | SSMDOR-2410 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Alarm System, Fire Safety, Power Supply |
Product Code | CPK-0100 |
FEATURES
• DIN Rail mountable redundancy module with schottky diode.
• Potenal free “NO” contact for each input.
• LED indication for each input and output.
• IP 20 protection and metal housing.
• 100% full load burn in test
SPECIFICATIONS
Input Characteriscs |
Input voltage range | 12-15VDC |
No of inputs | 2 | |
Maximum input current | 2X5A | |
No load current consump on |
<=0.05A (Type tested) | |
Input indicaon | Green LED | |
Output Characteristics |
Output current | 1X5A |
Heat dissipa on at nominal load |
8.5W | |
Output indicaon | Green LED | |
Input power supply status | Poten al free ‘NO’ contact (28VDC/300VAC-5A) |
|
Voltage drop across diode | 0.6V max at full load | |
Environmental Characteristics |
Ambient temperature (operati on) |
0°C +70°C |
Ambient temperature (storage) | 0°C +80°C | |
Relave humidity | 95% at 25 °C, no condensati on |
|
Cooling | Natural air convecti on |
|
General Characteristics |
Di-Electric strength | 1KVAC (Between input/output to body) |
Insulation resistance | 100mega Ohm @500VDC min. (Between input/output to body) |
|
Installation position | DIN Rail vertical mounti ng (DIN Rail TS-35/7.5 or 15) |
|
Type of connection |
Screw type connection (Make: Phoenix contact) |
|
Conductor cross section | 0.2 sq.mm-2.5 sq.mm for relay contact 0.2 sq.mm-4.0 sq.mm for input and output |
|
Weight | 0.45 Kg | |
Dimension (WXHXD) | Dimension (WXHXD) |
NOMENCLATURE & MOUNTING
No. | Description of function elements |
1 | Connection of input voltage: -IN1+ /-IN2+. |
2 | Relay contact: Max. 28VDC/300VAC-5A. |
3 | Connection of output voltage: DC -OUT+. |
4 | Indication: IN1 OK LED. |
5 | Indication: IN2 OK LED. |
6 | Indication: OUTPUT OK LED. |
SAFETY NOTES & WARNING INSTRUCTIONS
• Installation and start-up must only be carried out by qualified personnel.
• All incoming supply lines and output cables must have sufficient fuse protection.
• Minimum 5 cm space should be provided between other modules for sufficient convection.
• For connecting the redundancy module to the power supply, we recommend using two cables of the same length and with identical cross sections.
NOTE
1) All these parameters are specified at 12VDC @5A.
2) For continuous improvement, specifications are subject to change without prior intimation.
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping & Delivery Policy: |
1. | 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
4. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |