12V 05AMPS Doide ORing Module Redundant Power Supply | Sanstar

₹710.00 ₹837.80
In stock
More Information
Product Name12V 05AMPS Doide ORing Module Redundant Power Supply | Sanstar
Weight1.000000
COUNTRY OF MANUFACTUREIndia
BrandSanstar
HSN Code85044090
System TypeCONVENTIONAL
Modelssmdor-1205
Freight To pay by Customer, extra at actuals. Godown Delivery
CategoryAlarm System, Fire Safety, Power Supply
Product CodeCPK-0115
Freight Extra (Godown Delivery)
In Stock ( 100 Units )

FEATURES

• DIN Rail mountable redundancy module with schottky diode.

• Potential free “NO” contact for each input.

• LED indication for each input and output.

• IP 20 protection and metal housing.

•  100% full load burn in test

SPECIFICATIONS

Input
Characteristics
Nominal voltage 12VDC
Input voltage range 12-15VDC
No of inputs 2
Maximum input current 2X5A

No load current consumption

<=0.05A (Type tested)
Input indication Green LED
Output
Characteristics
Output current 1X5A

Heat dissipation at nominal load

8.5W
Output indication Green LED
Input power supply status Potential free ‘NO’ contact (28VDC/300VAC-5A)
Voltage drop across diode 0.6V max at full load
Environmental
Characteristics
Ambient temperature (operation) 0°C +70°C
Ambient temperature (storage) 0°C +80°C
Relative humidity 95% at 25 °C, no condensation
Cooling Natural air convection
General
Characteristics
Di-Electric strength 1KVAC (Between input/output to body)
Insulation resistance 100mega Ohm @500VDC min.
(Between input/output to body)
Installation position DIN Rail vertical mounting (DIN Rail TS-35/7.5 or 15)
Type of connection

Screw type connection (Make: Phoenix contact)

Conductor cross section 0.2 sq.mm-2.5 sq.mm for relay contact
0.2 sq.mm-4.0 sq.mm for input and output
Weight 0.45 Kg
Dimension (WXHXD) 46 X 81 X 81.5 mm

NOMENCLATURE & MOUNTING

No. Description of function elements
1 Connection of input voltage: -IN1+ /-IN2+.
2 Relay contact: Max. 28VDC/300VAC-5A.
3 Connection of output voltage: DC -OUT+.
4 Indication: IN1 OK LED.
5 Indication: IN2 OK LED.
6 Indication: OUTPUT OK LED.

SAFETY NOTES & WARNING INSTRUCTIONS

• Installation and start-up must only be carried out by qualified personnel.

• All incoming supply lines and output cables must have sufficient fuse protection.

• Minimum 5 cm space should be provided between other modules for sufficient convection.

• For connecting the redundancy module to the power supply, we recommend using two cables of the same length and with identical cross sections.

NOTE

1) All these parameters are specified at 12VDC @5A.

2) For continuous improvement, specifications are subject to change without prior intimation.

Returns Policy:
1. Once orders are placed, cancellations are not permitted.
2.  Payments for orders will not be adjusted or refunded in case of cancellation.
Shipping Policy:
1. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.
2.  Shipping freight costs will be additional and based on actuals, to be borne by the buyer.
3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis
Write Your Own Review
You're reviewing:12V 05AMPS Doide ORing Module Redundant Power Supply | Sanstar
Your Rating
WA button WA button