Schneider LC1E95 - 220V/415VAC coil Power Contactors 3 Pole "E' Series
₹9,664.60 ₹11,404.23
In stock
STOCK : In stock (%1 Units)
Product Name | Schneider LC1E95 - 220V/415VAC coil Power Contactors 3 Pole "E' Series |
---|---|
Weight | 1.000000 |
Brand | Schneider Electric |
Test Certificate | No |
COUNTRY OF MANUFACTURE | India |
HSN Code | 85369090 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Electrical, Relays & Contactor, Power Contactor |
Product Code | TNB-0317 |
Schneider LC1E95 - 220V/415VAC coil Power Contactors 3 Pole "E' Series
Easy TeSys contactor 3P(3 NO) - AC-3 - <= 440 V 95A - 220 V AC coil
Range | Easy TeSys |
---|---|
Range of product | Easy TeSys Control |
product or component type | Contactor |
Device short name | LC1E |
contactor application | Resistive load Motor control |
Utilisation category | AC-3 AC-1 |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current | 95 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 125 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 220 V AC 50 Hz |
Motor power kW | 45 kW at 415 V 45 kW at 440 V 45 kW at 500 V 25 kW at 220...230 V AC 50/60 Hz 45 kW at 380...400 V 55 kW at 660...690 V |
---|---|
Pole contact composition | 3 NO |
[Ith] conventional free air thermal current | 120 A (at 55 °C) |
Irms rated making capacity | 950 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 760 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 135 A 40 °C - 600 s for power circuit 800 A 40 °C - 10 s for power circuit 400 A 40 °C - 60 s for power circuit |
Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 160 A gG at <= 690 V coordination type 1 for power circuit |
Average impedance | 0.8 mOhm - Ith 120 A 50 Hz for power circuit |
Power dissipation per pole | 7.2 W AC-3 12 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 6 kV coil not connected to the power circuit conforming to IEC 60947 |
Mechanical durability | 3000000 cycles |
Electrical durability | 900000 cycles AC-3 350000 cycles AC-1 |
Control circuit type | AC at 50 Hz |
Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 50 Hz 0.3...0.6 Uc (-5…55 °C):drop-out 50 Hz |
Inrush power in VA | 200 VA 50 Hz cos phi 0.75 (at 20 °C) 220 VA 60 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 22 VA 60 Hz cos phi 0.3 (at 20 °C) 20 VA 50 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 6…10 W for control circuit |
Operating time | 20...35 ms on closing 6...30 ms on opening |
Maximum operating rate | 1200 cyc/h 60 °C |
Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 4…16 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4…50 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 4…50 mm² - cable stiffness: solid without cable end |
Tightening torque | Control circuit: 1.2 N.m Power circuit: 12 N.m |
Auxiliary contact composition | 1 NO + 1 NC |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
Mounting support | DIN rail Plate |
Standards | IEC 60947-5-1 IEC 60947-4-1 IEC 60947-1 |
---|---|
Product certifications | EAC CE |
IP degree of protection | IP2X conforming to IEC 60529 |
Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db |
Permissible ambient air temperature around the device | -20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
Operating altitude | 3000 m without derating |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Mechanical robustness | Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms) |
Height | 127 mm |
Width | 85 mm |
Depth | 121 mm |
net weight | 1.52 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 11.000 cm |
Package 1 Width | 15.000 cm |
Package 1 Length | 15.500 cm |
Package 1 Weight | 1.535 kg |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 5 |
Package 2 Height | 30.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 8.178 kg |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping Policy: |
1. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
Write Your Own Review
Brand: Schneider Electric
Sold By: