Schneider LC1E3801 - 220V/415VAC coil Power Contactors 3 Pole "E' Series
₹2,840.50 ₹3,351.79
In stock
STOCK : In stock (%1 Units)
Product Name | Schneider LC1E3801 - 220V/415VAC coil Power Contactors 3 Pole "E' Series |
---|---|
Weight | 1.000000 |
Brand | Schneider Electric |
Test Certificate | No |
COUNTRY OF MANUFACTURE | India |
HSN Code | 85369090 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Electrical, Relays & Contactor, Power Contactor |
Product Code | TNB-0312 |
Schneider LC1E3801 - 220V/415VAC coil Power Contactors 3 Pole "E' Series
LC1E3801E5 : EasyPact TVS contactor 3P(3 NO) - AC-3 - <= 440 V 38A - 48 V AC coil
Main | |
Range | Easy TeSys |
Range of product | Easy TeSys Control |
Product or component type | Contactor |
Device short name | LC1E |
Contactor application | Motor control Resistive load |
Utilisation category | AC-1 AC-3 |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current | 50 A (at <55 °C) at <= 440 V AC AC-1 for power circuit 38 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
[Uc] control circuit voltage | 48 V AC 50 Hz |
Complementary | |
Motor power kW | 18.5 KW at 500 V 18.5 KW at 660...690 V 9 KW at 220...230 V AC 50/60 Hz 18.5 KW at 380...400 V 18.5 KW at 415 V 18.5 KW at 440 V |
Pole contact composition | 3 NO |
[Ith] conventional free air thermal current | 50 A (at 55 °C) |
Irms rated making capacity | 380 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 304 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 60 A 40 °C - 600 s for power circuit 310 A 40 °C - 10 s for power circuit 150 A 40 °C - 60 s for power circuit |
Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming- to IEC 60947-5-1 63 A gG at <= 690 V coordination type 1 for power circuit |
Average impedance | 2.5 MOhm - Ith 50 A 50 Hz for power circuit |
Power dissipation per pole | 2.9 W AC-35 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 6 KV coil not connected to the power circuit conforming to IEC 60947 |
Mechanical durability | 8000000 Cycles |
Electrical durability | 350000 Cycles AC-1 900000 Cycles AC-3 |
Control circuit type | AC at 50 Hz |
Control circuit voltage limits | 0.85...1.1 Uc (55 °C):operational 50 Hz 0.3...0.6 Uc (55 °C):drop-out 50 Hz |
Inrush power in VA | 95 VA 50 Hz cos phi 0.75 (at 20 °C) 95 VA 60 Hz cos phi 0.75 (at 20 °C) |
Hold-in power consumption in VA | 8.3 VA 50 Hz cos phi 0.3 (at 20 °C) 8.5 VA 60 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 2…3 W for control circuit |
Operating time | 12...22 ms on closing 4...19 ms on opening |
Maximum operating rate | 1800 Cyc/H 60 °C |
Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with- cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible- with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without- cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without- cable end Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 1.5…6 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: flexible with- cable end Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible with- cable en |
Tightening torque | Control circuit: 1.2 N.m Power circuit: 2.1 N.m |
Auxiliary contact composition | 1 NC |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 MA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 Ms on energisation guaranteed between NC and NO contact 1.5 Ms on de-energisation guaranteed between NC and NO contact |
Mounting support | DIN rail Plate |
Environment | |
Standards | IEC 60947-1 IEC 60947-4-1 IEC 60947-5-1 |
Product certifications | EAC[RETURN]CE |
IP degree of protection | IP2X conforming to IEC 60529 |
Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db |
Permissible ambient air temperature around the device | -20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
Operating altitude | 3000 m without derating |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Mechanical robustness | Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms) |
Height | 84 Mm |
Width | 56 Mm |
Depth | 86 Mm |
Net weight | 0.45 Kg |
Packing Units | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 8.6 Cm |
Package 1 Width | 8.4 Cm |
Package 1 Length | 5.6 Cm |
Package 1 Weight | 449 G |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 24 |
Package 2 Height | 15 Cm |
Package 2 Width | 30 Cm |
Package 2 Length | 40 Cm |
Package 2 Weight | 11.184 Kg |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping Policy: |
1. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
Write Your Own Review
Brand: Schneider Electric
Sold By: