Schneider LC1E250 - 220V/415VAC coil Power Contactors 3 Pole "E' Series
₹32,591.00 ₹38,457.38
In stock
STOCK : In stock (%1 Units)
Product Name | Schneider LC1E250 - 220V/415VAC coil Power Contactors 3 Pole "E' Series |
---|---|
Weight | 1.000000 |
Brand | Schneider Electric |
Test Certificate | No |
COUNTRY OF MANUFACTURE | India |
HSN Code | 85369090 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Electrical, Relays & Contactor, Power Contactor |
Product Code | TNB-0321 |
Schneider LC1E250 - 220V/415VAC coil Power Contactors 3 Pole "E' Series
Contactor,Easy TeSys Control,LC1E,3P(3NO),AC-3,<=440V,250A,220V AC coil,60Hz
Range | Easy TeSys |
---|---|
Range of product | Easy TeSys Control |
product or component type | Contactor |
Device short name | LC1E |
contactor application | Motor control Resistive load |
Utilisation category | AC-3 AC-1 |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current | 250 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 300 A (at <40 °C) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 220 V AC 60 Hz |
Motor power kW | 75 kW at 220...230 V AC 50/60 Hz 132 kW at 380...400 V 140 kW at 415 V 140 kW at 440 V 160 kW at 500 V 160 kW at 660...690 V |
---|---|
Pole contact composition | 3 NO |
[Ith] conventional free air thermal current | 36 A (at 55 °C) |
Irms rated making capacity | 2500 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 2000 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 1800 A 40 °C - 10 s for power circuit |
Associated fuse rating | 10 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 315 A gG at <= 690 V coordination type 1 for power circuit |
Average impedance | 0.32 mOhm - Ith 300 A 50 Hz for power circuit |
Power dissipation per pole | 20 W AC-3 29 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 8 kV coil not connected to the power circuit conforming to IEC 60947 |
Mechanical durability | 5000000 cycles |
Electrical durability | 200000 cycles AC-1 700000 cycles AC-3 |
Control circuit type | AC at 60 Hz |
Control circuit voltage limits | 0.85...1.1 Uc (-5…55 °C):operational 60 Hz 0.35...0.55 Uc (-5…55 °C):drop-out 60 Hz |
Inrush power in VA | 805 VA 50 Hz cos phi 0.3 (at 20 °C) 970 VA 60 Hz cos phi 0.3 (at 20 °C) |
Hold-in power consumption in VA | 55 VA 50 Hz cos phi 0.3 (at 20 °C) 66 VA 60 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 18…24 W for control circuit |
Operating time | 20...35 ms on closing 7...15 ms on opening |
Maximum operating rate | 1200 cyc/h 55 °C |
Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end Power circuit: cable with lug - external diameter: 185 mm Power circuit: bars 2 - busbar cross section: 32 x 4 mm |
Tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
Mounting support | Plate |
Standards | IEC 60947-1 IEC 60947-4-1 IEC 60947-5-1 |
---|---|
Product certifications | EAC CE |
IP degree of protection | IP00 conforming to IEC 60529 |
Permissible ambient air temperature around the device | -20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
Operating altitude | 3000 m without derating |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Mechanical robustness | Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms) |
Height | 197 mm |
Width | 168.5 mm |
Depth | 181 mm |
net weight | 4.7 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 18.1 cm |
Package 1 Width | 16.85 cm |
Package 1 Length | 17.4 cm |
Package 1 Weight | 6.01 kg |
Unit Type of Package 2 | PAL |
Number of Units in Package 2 | 12 |
Package 2 Height | 70.0 cm |
Package 2 Width | 60.0 cm |
Package 2 Length | 80.0 cm |
Package 2 Weight | 82.1 kg |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping & Delivery Policy: |
1. | 100 INR will be charged as shipping fee if buyer and seller are from same city. If Buyer and Seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
4. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |
Write Your Own Review