Schneider LC1E120 - 220V/415VAC coil Power Contactors 3 Pole "E' Series
₹11,513.80 ₹13,586.28
In stock
STOCK : In stock (%1 Units)
Product Name | Schneider LC1E120 - 220V/415VAC coil Power Contactors 3 Pole "E' Series |
---|---|
Weight | 1.000000 |
Brand | Schneider Electric |
Test Certificate | No |
COUNTRY OF MANUFACTURE | India |
HSN Code | 85369090 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Electrical, Relays & Contactor, Power Contactor |
Product Code | TNB-0318 |
Schneider LC1E120 - 220V/415VAC coil Power Contactors 3 Pole "E' Series
Easy TeSys contactor 3P(3 NO) - AC-3 - <= 440 V 120A - 48 V AC coil
Range | Easy TeSys |
---|---|
Range of product | Easy TeSys Control |
product or component type | Contactor |
Device short name | LC1E |
contactor application | Motor control Resistive load |
Utilisation category | AC-1 AC-3 |
Poles description | 3P |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 50/60 Hz |
[Ie] rated operational current | 120 A (at <55 °C) at <= 440 V AC AC-3 for power circuit 150 A (at <55 °C) at <= 440 V AC AC-1 for power circuit |
[Uc] control circuit voltage | 48 V AC 50 Hz |
Motor power kW | 37 kW at 220...230 V AC 50/60 Hz (AC-3) 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415 V AC 50/60 Hz (AC-3) 59 kW at 440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) |
---|---|
Pole contact composition | 3 NO |
[Ith] conventional free air thermal current | 25 A (at 55 °C) for power circuit |
Irms rated making capacity | 1200 A at 440 V AC for power circuit conforming to IEC 60947-4-1 |
Rated breaking capacity | 960 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 1100 A 40 °C - 10 s for power circuit |
Associated fuse rating | 250 A gG at <= 690 V coordination type 1 for control circuit conforming to IEC 60947-5-1 10 A gG at <= 690 V coordination type 1 for power circuit |
Average impedance | 0.6 mOhm - Ith 150 A 50 Hz for power circuit |
Power dissipation per pole | 8.6 W AC-3 14 W AC-1 |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
Overvoltage category | III |
Pollution degree | 3 |
[Uimp] rated impulse withstand voltage | 8 kV coil not connected to the power circuit conforming to IEC 60947 |
Mechanical durability | 4000000 cycles |
Electrical durability | 800000 cycles AC-3 250000 cycles AC-1 |
Control circuit type | AC at 50 Hz |
Control circuit voltage limits | 0.85...1.1 Uc (55 °C):operational 50 Hz 0.35...0.55 Uc (55 °C):drop-out 50 Hz |
Inrush power in VA | 300 VA 50 Hz cos phi 0.8 (at 20 °C) 300 VA 60 Hz cos phi 0.8 (at 20 °C) |
Hold-in power consumption in VA | 22 VA 50 Hz cos phi 0.3 (at 20 °C) 22 VA 60 Hz cos phi 0.3 (at 20 °C) |
Heat dissipation | 3…8 W for control circuit |
Operating time | 20...50 ms on closing 6...20 ms on opening |
Maximum operating rate | 1200 cyc/h 55 °C |
Connections - terminals | Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 20…170 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 10…120 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 2 20…170 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end |
Tightening torque | Power circuit: 12 N.m Control circuit: 1.2 N.m |
Auxiliary contact composition | 1 NO + 1 NC |
Minimum switching voltage | 17 V for control circuit |
Minimum switching current | 5 mA for control circuit |
Insulation resistance | > 10 MOhm for control circuit |
Non-overlap time | 1.5 ms on energisation guaranteed between NC and NO contact 1.5 ms on de-energisation guaranteed between NC and NO contact |
Mounting support | DIN rail Plate |
Standards | IEC 60947-1 IEC 60947-4-1 IEC 60947-5-1 |
---|---|
Product certifications | CE EAC |
IP degree of protection | IP2X conforming to IEC 60529 |
Protective treatment | TH (pollution degree 3) conforming to IEC 60068-2-30 |
Permissible ambient air temperature around the device | -20…70 °C at Uc -60…80 °C storage -5…55 °C operation |
Operating altitude | 3000 m without derating |
Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Mechanical robustness | Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms) |
Height | 158 mm |
Width | 120 mm |
Depth | 132 mm |
net weight | 2.3 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 19 cm |
Package 1 Width | 17.5 cm |
Package 1 Length | 21 cm |
Package 1 Weight | 2.3 kg |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping Policy: |
1. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |
3. | Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis |
Write Your Own Review
Brand: Schneider Electric
Sold By: