Device Loop card XDLC | Fire Alarm Control Panel | Siemens
Product Name | Device Loop card XDLC | Fire Alarm Control Panel | Siemens |
---|---|
Weight | 1.000000 |
COUNTRY OF MANUFACTURE | India |
Brand | Siemens |
HSN Code | 85319000 |
System Type | CONVENTIONAL |
Model | XDLC-S54430-B8-A1 |
Freight | To pay by Customer, extra at actuals. Godown Delivery |
Category | Alarm System, Fire Safety, Control Module, Loop Card |
Product Code | CPK-0025 |
Supports up to 252 addressable points
Operates and maintains all devices residing on up to four (4) `Class A’, eight(8) `Class B’ addressable circuits
Compatible with Siemens intelligent, addressable ‘X’ and ‘H’-series devices:
- Multi-criteria / Carbon Monoxide (CO) Detector with ASAtechnologyTM
- Multi-criteria Detector with ASAtechnologyTM
- Multi-criteria Detector
- Thermal (Heat) Detector
- Input / Output Interface Module
Polarity insensitive (in non-isolation mode) via SureWireTM technology:
- Modern technology supports comprehensive system and interface communication
Quantity 16 diagnostic light-emitting diodes (LEDs) for easy circuit diagnosis
Microchip controls on-board isolators
Device Programmer / Tester (Model DPU) programs and verifies device’s address:
- programming capabilities include testing a duct detector, as well as other Siemens addressable devices
Supports `Class B’ | `Class A’ | `Class X’ wiring
Supports T-Tapping
Degrade mode
UL864 | CAN / ULC Listed
The Siemens – Fire Safety `Class X’ Device Loop Card (Model XDLC) is the interface used for connecting Siemens addressable, intelligent `X’ as well as `H’-series devices.
Each Model XDLC plugs into one (1) slot of the Model CC-2 or Model CC-5 card cage. Programming for Model XDLC is accomplished via the Desigo Fire Safety Modular system custom-configuration tool, Zeus-D. Model XDLC takes one (1) address on the network, communicating up to a total 252 detectors and devices. Model XDLC has 16 LEDs for diagnostic purposes, and provides ground-fault detection and zone- isolation circuitry.
Specifications
The `Class X’ Device Loop Card (Model XDLC) initializes, operates and maintains all devices residing on up to four (4) `Class A’, eight (8) `Class B’ addressable circuits. Model XDLC communicates all relevant device and event data (`Alarm’, `Trouble’ and`Supervisory’ commands) to a Desigo Fire Safety Modular (Desigo Modular) fire- alarm control panel (FACP), and supervises the device loop circuit.
Model XDLC is polarity insensitive via SureWire technology, which greatly reduces commissioning time normally spent tracing down crossed-field wiring. Model XDLC communicates detector data, such as sensitivity of intelligent fire detectors and logic-function information, to the Desigo Modular Operating Unit (Model FCM2041- U2), which is located within a given Desigo Modular system. Each device loop card supports four (4) `Class A’, eight (8) `Class B’ circuits for up to a total of 252 addressable devices – as well as relay and audible bases, remote lamps and duct-detector housings in any combination.
The microprocessor in a Model XDLC controls the on-board isolation, in case there is a fault (short) in any of the circuits, thus allowing the other circuit to continue operating. For continuous protection,
the on-board microprocessor continues to operate even in the event of a CPU failure.
Technical Data
24V CURRENT DRAW: [Back Plane] |
0 |
24V CURRENT DRAW: [Screw Terminal] |
100mA + 1.4mA per device |
6.2V CURRENT DRAW: [Back Plane] |
1mA, max. |
24V CURRENT DRAW: [Standby] |
100mA + 1.4mA per device |
DEVICE LOOP: [@ 30 VDC Max.] |
500mA, max. (power limited) |
Returns Policy: |
1. | Once orders are placed, cancellations are not permitted. |
2. | Payments for orders will not be adjusted or refunded in case of cancellation. |
Shipping Policy: |
1. | Material will be shipped exclusively on a To-Pay basis for Godown Delivery only. |
2. | Shipping freight costs will be additional and based on actuals, to be borne by the buyer. |