Product Description

LC1D65 220 AC coil Power Contactors 3 Pole "D" Series Schneider - Strategic Industrial Guidance

LC1D65 220 AC coil Power Contactors

LC1D65 220 AC coil Power Contactors 3 Pole "D" Series Schneider


LC1D65D7 : contactor TeSys Deca - 3 poles - AC-3 440V 65 A - coil 42 V AC

Main
Range TeSys
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Motor control
Utilisation category AC-2
AC-1
AC-4
AC-3
Poles description 3P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
65 A (at <60 °C) DC AC-3 for power circuit
80 A (at <60 °C) DC AC-1 for power circuit
[Uc] control circuit voltage 42 V DC

Complementary
Motor power kW 11 KW at 400 V AC 50 Hz (AC-4)
30 KW at 380...400 V AC 50 Hz (AC-3)
37 KW at 500 V AC 50 Hz (AC-3)
37 KW at 660...690 V AC 50 Hz (AC-3)
18.5 KW at 220...230 V AC 50 Hz (AC-3)
30 KW at 415 V AC 50 Hz (AC-3)
37 KW at 1000 V AC 50 Hz (AC-3)
37 KW at 500 V AC 50 Hz
30 KW at 380...400 V AC 50 Hz
Motor power hp 10 Hp at 230/240 V AC 60 Hz for 1 phase motors
20 Hp at 200/208 V AC 60 Hz for 3 phases motors
20 Hp at 230/240 V AC 60 Hz for 3 phases motors
40 Hp at 460/480 V AC 60 Hz for 3 phases motors
50 Hp at 575/600 V AC 60 Hz for 3 phases motors
5 Hp at 115 V AC 60 Hz for 1 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 80 A (at 60 °C) for power circuit
10 A (at 60 °C) for control circuit
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
16-May-2024
1
Irms rated making capacity 140 A AC for control circuit conforming to IEC 60947-5-1
1000 A at 440 V for power circuit conforming to IEC 60947
250 A DC for control circuit conforming to IEC 60947-5-1
Rated breaking capacity 1000 KA at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 520 A 40 °C - 10 s for power circuit
900 A 40 °C - 1 s for power circuit
Associated fuse rating 125 A gG at <= 690 V coordination type 2 for power circuit
160 A gG at <= 690 V coordination type 1 for power circuit conforming-
to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for control circuit conforming to IEC 60947-5-1
Average impedance 1.5 Ohm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole 6.4 W AC-1
6.3 W AC-3
9.6 W AC-1
[Ui] rated insulation voltage Control circuit: 600 V UL certified[RETURN]Power circuit: 600 V CSA certified[RETURN]Power circuit: 600 V UL certified conforming to IEC 60947-1[RETURN]Control circuit: 690 V conforming to IEC 60947-1[RETURN]Power circuit: 690 V CSA certified conforming to IEC 60947-1[RETURN]Control circuit: 600 V CSA certified
Overvoltage category III
[Uimp] rated impulse withstand voltage 6 KV conforming to IEC 60947
Safety reliability level B10d = 20000000 cycles contactor with mechanical load conforming-
to EN/ISO 13849-1
Mechanical durability 10000000 Cycles
Control circuit type DC standard
Coil technology Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
0.75...1.25 Uc (-40…60 °C):operational DC
0.1...0.3 Uc (-40…70 °C):drop-out DC
Inrush power in VA 160 VA cos phi 0.75 (at 20 °C)
Inrush power in W 19 W (at 20 °C)
Hold-in power consumption in VA 15 VA 50 Hz cos phi 0.3 (at 20 °C)
Hold-in power consumption in W 7.4 W at 20 °C
Heat dissipation 4…5 W at 50/60 Hz for control circuit
Operating time 12...26 ms closing
4...19 ms opening
Maximum operating rate 3600 Cyc/Mn 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: rigid without-
cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible-
with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible-
with cable end
Power circuit: screw terminals 1 2.5…25 mm² - cable stiffness: rigid
Power circuit: screw terminals 2 2.5…16 mm² - cable stiffness: rigid without cable end
Power circuit: screw terminals 1 2.5…25 mm² - cable stiffness: flexible without-
cable end
Power circuit: screw terminals 2 2.5…16 mm² - cable stiffness: flexible without-
cable end
Power circuit: screw terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: rigid
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: rigid
Tightening torque Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2
Power circuit: 5 N.m - on screw terminal - with screwdriver flat Ø 6 to Ø 8 mm
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver pozidriv No 2
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Type mirror contact 1 NC conforming to IEC 60947-4-1
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
2
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 MA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 Ms on energisation between NC and NO contacts
1.5 Ms on de-energisation between NC and NO contacts
Mounting support Plate
Plate

Environment
Standards UL 508
EN 60947-5-1
CSA C22.2 No 14
IEC 60947-5-1
EN 60947-4-1
Product certifications GOST[RETURN]UL[RETURN]BV[RETURN]RINA[RETURN]LROS (Lloyds register of shipping)[RETURN]GL[RETURN]DNV[RETURN]CSA[RETURN]UL
IP degree of protection IP2X conforming to VDE 0106
IP2X conforming to IEC 60529
Protective treatment TH (pollution degree 3) conforming to IEC 60068-2-30
Climatic withstand Conforming to IACS E10 exposure to damp heat
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor closed (15 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor opened (10 Gn for 11 ms)
Height 122 Mm
Width 70 Mm
Depth 118 Mm
Net weight 2.185 Kg
Quantity per set Set of 1

Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14 Cm
Package 1 Width 13.5 Cm
Package 1 Length 9.5 Cm
Package 1 Weight 1.456 Kg

Returns & Cancellation

Returns Policy:

1. Once orders are placed, cancellations are not permitted.

2. Payments for orders will not be adjusted or refunded in case of cancellation.

Shipping & Delivery Policy:

1. 100 INR will be charged as shipping fee if buyer and seller are from same city. If buyer and seller are from different cities, the shipping charges will be on "To Pay Basis" or at actuals.

2. Shipping freight costs will be additional and based on actuals, to be borne by the buyer.

3. Additional shipping services such as courier or door delivery will incur extra charges, to be borne by buyer on extra at actuals basis.

4. Material will be shipped exclusively on a To-Pay basis for Godown Delivery only.

Feedback

You're reviewing: LC1D65 220 AC coil Power Contactors 3 Pole "D" Series Schneider

Your Rating *

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.